Parameter list
PNU
Description
11.87 Configuring the EB2 expansion board
n773
Display of status of binary inputs and outputs on EB2
(2773)
Representation on operator panel (PMU):
(Z118)
(Z119)
Segment ON:
Segment OFF:
Segment or bit
0 ........ Terminal 53
1 ........ Terminal 54
2 ........ Terminal 39
3 ........ Terminal 41
4 ........ Terminal 43
5 ........ Terminal 45
i001:
Terminal states of first EB2
i002:
Terminal states of second EB2
Source for output values at binary outputs on EB2 [SW 1.5 and later]
U774
(2774)
Selection of binectors to be applied to binary outputs at terminals 39 - 46.
*
0 = binector B0000
1 = binector B0001
etc.
(Z118)
(Z119)
i001: BO1 of the first EB2
i002: BO2 of the first EB2
i003: BO3 of the first EB2
i004: BO4 of the first EB2
i005: BO1 of the second EB2
i006: BO2 of the second EB2
i007: BO3 of the second EB2
i008: BO4 of the second EB2
U775
Signal type of analog input on EB2
(2775)
0 = voltage input 0 to ± 10 V
1 = current input 0 to ± 20 mA
*
(Z118)
i001: AI1 of the first EB2
(Z119)
i002: AI1 of the second EB2
U776
Normalization of analog input on EB2
(2776)
This parameter specifies the percentage value which is generated for an
input voltage of 10V (or an input current of 20mA) at the analog input.
(Z118)
The following general rule applies:
(Z119)
With a voltage input:
[%] =
U
776
10
With a current input:
[%] =
U
776
20
i001: AI of the first EB2
i002: AI of the second EB2
11-168
4
3
2
5
Corresponding terminal is activated
(HIGH level is applied)
Corresponding terminal is not activated
(LOW level is applied)
Y
X .. input voltage in volts
V
X
Y .. % value which is generated for input
voltage X
Y
X .. input current in mA
mA
X
Y .. % value which is generated for input
current X
[SW 1.5 and later]
1
0
[SW 1.5 and later]
[SW 1.5 and later]
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
Ind: 2
Type: V2
All binector numbers
Ind: 8
1
FS=0
Type: L2
0 to 1
Ind: 2
1
FS=0
Type: O2
-1000.0 to 1000.0
Ind: 2
[%]
FS=100.0
0.1%
Type: I2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
6RX1700-0AD76