05.05
PNU
Description
P794
Source for transmit data for G-SST2
*
Selection of connectors to be transferred as transmit data via basic
(G171)
converter interface 2
(G173)
When USS protocol (P790=2) is selected:
i001:
Selection for word 1
i002:
Selection for word 2
...
i016:
Selection for word 16
When peer-to-peer (P790=5) is selected:
i001:
Selection for word 1
i002:
Selection for word 2
...
i005:
Selection for word 5
i006:
Not used
...
i016:
Not used
Applicable settings:
0 = connector K0000
1 = connector K0001
etc.
P795
Options for G-SST2
i001:
0 = Bus terminator OFF
(G171)
1 = Bus terminator ON
(G173)
i002:
0 = Bit 10 of the 1
by PLC".
1 = Bit 10 of the 1
PLC", i.e. when bit 10 = 0, all other bits of the 1
as well as receive words 2 to 16, are not written to connectors
K6001 to K6016, or to binectors B6100 to B6915. All these
connectors and binectors retain their old values.
P796
USS bus address for G-SST2
*
This parameter is functional only when P790=2 (USS protocol). Address via
(G171)
which the unit can be addressed in USS bus operation.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
st
receive word does not function as "Control
st
receive word does function as "Control by
Value range
[Unit]
Steps
All connector
numbers
1
0 to 1
1
st
receive word,
0 to 30
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 16
P052 = 3
FS=
P051 = 40
i001: 32
Offline
i002: 167
i003: 0
i004: 33
i005-i016: 0
Type: L2
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
11-85