05.05
PNU
Description
th
sign inverter (result = K9138)
U138
Source for 4
(2138)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B125)
Switchable sign inverters
The contents of the connector entered in the parameter for selection of a source is switched through, depending on the state of the
binector entered in the parameter for control bit selection, as an unchanged value (when control bit = 0) or as a negated value (two's
complement, when control bit = 1). The result is applied to the specified connector.
st
U140
Source for 1
switchable sign inverter
(2140)
Result = K9140
*
S00
0 = connector K0000
(B125)
1 = connector K0001
etc.
U141
Control bit for 1
(2141)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B125)
nd
U142
Source for 2
switchable sign inverter
(2142)
Result = K9141
*
S00
0 = connector K0000
(B125)
1 = connector K0001
etc.
U143
Control bit for 2
(2143)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B125)
Divider
The two operands (x1, x2) for each divider are selected via 2 indices each of the parameter:
Index i001 = x1, index i002 = x2
Index i003 = x1, index i004 = x2 [SW 1.8 and later]
x
1 100%
=
Formula: y
y is limited to -200.00 to +199.99% and applied to the connector stated.
Operands for 1st divider (result = K9145)
U145
(2145)
Operands for 4th divider (result = K9142)
*
0 = Connector K0000
S00
1 = Connector K0001
(B131)
etc.
Operands for 2nd divider (result = K9146)
U146
(2146)
Operands for 5th divider (result = K9143)
*
0 = Connector K0000
S00
1 = Connector K0001
(B131)
etc.
Operands for 3rd divider (result = K9147)
U147
(2147)
Operands for 6th divider (result = K9144)
*
0 = Connector K0000
S00
1 = Connector K0001
(B131)
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
st
switchable sign inverter
nd
switchable sign inverter
x
2
Value range
[Unit]
Steps
All connector
FB 38
numbers
1
All connector
FB 40
numbers
1
All binector numbers
FB 40
1
All connector
FB 41
numbers
1
All binector numbers
FB 41
1
For division by 0 (x2=0) the following applies:
for x1 > 0: y = +199.99%
for x1 = 0: y = 0.00%
for x1 < 0: y = -200.00%
All connector
FB 45
numbers
FB 42
1
All connector
FB 46
numbers
FB 43
1
All connector
FB 47
numbers
FB 44
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 4
P052 = 3
P051 = 40
FS=1
off-line
Type: L2
Ind: 4
P052 = 3
P051 = 40
FS=1
off-line
Type: L2
Ind: 4
P052 = 3
P051 = 40
FS=1
off-line
Type: L2
11-109