Siemens 6RA7086-6KS22 Operating Instructions Manual page 590

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
U288
x values
(2288)
i001
1st characteristic point
S00
i002
2nd characteristic point
...
(B160)
i010
10th characteristic point
SW 1.8 and later:
i011
1st characteristic point
i012
2nd characteristic point
...
i020
10th characteristic point
i021
1st characteristic point
i022
2nd characteristic point
...
i030
10th characteristic point
U289
y values
(2289)
i001
1st characteristic point
S00
i002
2nd characteristic point
...
(B160)
i010
10th characteristic point
SW 1.8 and later:
i011
1st characteristic point
i012
2nd characteristic point
...
i020
10th characteristic point
i021
1st characteristic point
i022
2nd characteristic point
...
i030
10th characteristic point
Dead zones
The component of the input quantity (x) whose absolute value exceeds the threshold for the dead zone is applied to the output (y).
Dead zone 1 (output = K9232)
U290
Source for input quantity
(2290)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B161)
U291
Dead zone
(2291)
S00
(B161)
Dead zone 2 (output = K9233)
U292
Source for input quantity
(2292)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B161)
U293
Dead zone
(2293)
S00
(B161)
Dead zone 3 (output = K9234)
U294
Source for input quantity
(2294)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B161)
U295
Dead zone
(2295)
S00
(B161)
11-126
for FB108
for FB108
for FB108
for FB284
for FB284
for FB284
for FB285
for FB285
for FB285
for FB108
for FB108
for FB108
for FB284
for FB284
for FB284
for FB285
for FB285
for FB285
Value range
[Unit]
Steps
-200.00 to 199.99
[%]
0.01
-200.00 to 199.99
[%]
0.01
All connector
FB 109
numbers
1
FB 109 0.00 to 100.00
[%]
0.01
All connector
FB 110
numbers
1
FB 110 0.00 to 100.00
[%]
0.01
All connector
FB 111
numbers
1
FB 111 0.00 to 100.00
[%]
0.01
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 30
P052 = 3
FS=0.00
P051 = 40
Type: I2
on-line
Ind: 30
P052 = 3
FS=0.00
P051 = 40
Type: I2
on-line
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0.00
P051 = 40
Type: O2
Online
6RX1700-0AD76
Operating Instructions