Siemens 6RA7086-6KS22 Operating Instructions Manual page 655

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
Connector
Description
EMF setpoint
K0289
Motor flux
K0290
K0291
Absolute actual armature voltage
K0292
Signed actual armature voltage
K0293
Precontrol output (EMF)
General connectors
K0301
Line voltage U-V (armature)
Line voltage V-W (armature)
K0302
Line voltage W-U (armature)
K0303
K0304
Line voltage (field)
K0305
Average line voltage (armature), filtered
Line frequency
K0306
K0307
Motor power output
Normalization: 16384
K0309
Calculated motor temperature rise
Normalization: 16384
K0310
Calculated thyristor temperature rise as % of maximum permissible thyristor
temperature rise
Hours run
K0311
Fixed setpoints
K0401
Fixed value 1 (P401)
K0402
Fixed value 2 (P402)
Fixed value 3 (P403)
K0403
Fixed value 4 (P404)
K0404
K0405
Fixed value 5 (P405)
K0406
Fixed value 6 (P406)
K0407
Fixed value 7 (P407)
Fixed value 8 (P408)
K0408
Fixed value 9 (P409)
K0409
K0410
Fixed value 10 (P410)
K0411
Fixed value 11 (P411)
Fixed value 12 (P412)
K0412
Fixed value 13 (P413)
K0413
K0414
Fixed value 14 (P414)
K0415
Fixed value 15 (P415)
K0416
Fixed value 16 (P416)
Start pulse for the speed controller
K0451
Fixed setting value 1 for the n controller I component
Setting value 1 for the n controller I component, weighted
K0452
Fixed setting value 2 for the n controller I component
K0453
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
∧ P100 * (P101 – P100 * P110)
=
∧ the overtemperature which is reached at a
=
continuous current corresponding to the rated motor armature
current
Normalization
16384
16384
100% motor flux is reached
at rated motor field current
(P102)
16384
16384
16384
16384
16384
16384
16384
16384
16384
see Column 2
see Column 2
16384
∧ 1h
=
[SW 1.9 and later]
1
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
16384
Connectors and binectors
Function
diag., Sheet
G165
∧ P078.001
3 2
=
π
*
∧ 100%
=
G166
∧ P078.001
3 2
=
π
*
∧ P078.001
3 2
=
π
*
∧ 100%
=
G165
∧ P078.001
=
∧ P078.001
=
∧ P078.001
=
∧ 400V
=
∧ P078.001
=
∧ 50.0Hz
=
∧ 100%
=
G189
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
∧ 100%
=
G120
[SW 1.7 and later]
∧ 100% of P100
=
G150
∧ 100% of P100
=
G150
∧ 100% of P100
=
G150