Siemens 6RA7086-6KS22 Operating Instructions Manual page 633

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
U777
Offset for analog input on EB2
(2777)
i001: AI of the first EB2
i002: AI of the second EB2
(Z118)
(Z119)
U778
Mode of signal injection at analog input on EB2
(2778)
0 = Injection of signal with sign
1 = Injection of absolute value of signal
*
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
(Z118)
(Z119)
i001: AI of the first EB2
i002: AI of the second EB2
U779
Source for selection of sign reversal at
analog input on EB2
(2779)
Selection of binector to control sign reversal at the analog input ("1" state
*
= reverse sign)
(Z118)
(Z119)
0 = binector B0000
1 = binector B0001
etc.
i001: AI of the first EB2
i002: AI of the second EB2
U780
Filtering time for analog input on EB2
(2780)
Note: Hardware filtering of approximately 0.2 ms is applied as standard
(Z118)
i001: AI of the first EB2
(Z119)
i002: AI of the second EB2
U781
Source for enabling of analog inputs on EB2
(2781)
Selection of binector to control enabling of the analog input ("1" state =
enabled)
*
0 = binector B0000
1 = binector B0001
(Z118)
etc.
(Z119)
i001: AI of the first EB2
i002: AI of the second EB2
n782
Display of analog input on EB2
(2782)
i001: AI of the first EB2
i002: AI of the second EB2
(Z118)
(Z119)
U783
Source for output value at analog output on EB2
(2783)
Selection of connector whose value must be output at the analog output
*
0 = connector K0000
1 = connector K0001
etc.
(Z118)
(Z119)
i001: AO of the first EB2
i002: AO of the second EB2
U784
Mode of signal injection at analog output on EB2
(2784)
0 = Injection of signal with sign
1 = Injection of absolute value of signal
*
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
(Z118)
(Z119)
i001: AO of the first EB2
i002: AO of the second EB2
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
[SW 1.5 and later]
-100.00 to 100.00
[%]
0.01%
0 to 3
[SW 1.5 and later]
1
[SW 1.5 and later]
All binector numbers
1
0 to 10000
[SW 1.5 and later]
[ms]
1ms
[SW 1.5 and later]
All binector numbers
1
[SW 1.5 and later]
-200.0 to 199.99
[%]
0.01%
[SW 1.5 and later]
All connector
numbers
1
[SW 1.5 and later]
0 to 3
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=0.00
P051 = 40
Type: I2
Online
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: O2
Online
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
Type: I2
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Online
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: O2
Online
11-169