05.05
PNU
Description
U418
Source for SET and RESET for RS flipflop 4
(2418)
(outputs: Q = B9556, /Q = B9557)
*
As for U415
S00
(B210)
U419
Source for SET and RESET for RS flipflop 5
(2419)
(outputs: Q = B9558, /Q = B9559)
*
As for U415
S00
(B210)
U420
Source for SET and RESET for RS flipflop 6
(2420)
(outputs: Q = B9560, /Q = B9561)
*
As for U415
S00
(B210)
U421
Source for SET and RESET for RS flipflop 7
(2421)
(outputs: Q = B9562, /Q = B9563)
*
As for U415
S00
(B210)
U422
Source for SET and RESET for RS flipflop 8
(2422)
(outputs: Q = B9564, /Q = B9565)
*
As for U415
S00
(B210)
U423
Source for SET and RESET for RS flipflop 9
(2423)
(outputs: Q = B9566, /Q = B9567)
*
As for U415
S00
(B210)
U424
Source for SET and RESET for RS flipflop 10
(2424)
(outputs: Q = B9568, /Q = B9569)
*
As for U415
S00
(B210)
U425
Source for SET and RESET for RS flipflop 11
(2425)
(outputs: Q = B9570, /Q = B9571)
*
As for U415
S00
(B210)
U426
Source for SET and RESET for RS flipflop 12
(2426)
(outputs: Q = B9572, /Q = B9573)
*
As for U415
S00
(B210)
U427
Source for SET and RESET for RS flipflop 13
(2427)
(outputs: Q = B9574, /Q = B9575)
*
As for U415
S00
(B210)
U428
Source for SET and RESET for RS flipflop 14
(2428)
(outputs: Q = B9576, /Q = B9577)
*
As for U415
S00
(B210)
D flipflops
D flipflops with RESET (Q=0), SET (Q=1) and STORE (Q=D on transition from 0 to 1) (priority: 1
RESET setting is enabled on POWER ON.
U430
Source for SET, D, STORE and RESET for D flipflop 1
(2430)
(outputs: Q = B9490, /Q = B9491)
*
i001
Source for SET
S00
i002
Source for D
i003
Source for STORE
(B211)
i004
Source for RESET
Settings:
0 = binector B0000
1 = binector B0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
All binector numbers
FB 218
1
All binector numbers
FB 219
1
All binector numbers
FB 220
1
All binector numbers
FB 221
1
All binector numbers
FB 222
1
All binector numbers
FB 223
1
All binector numbers
FB 224
1
All binector numbers
FB 225
1
All binector numbers
FB 226
1
All binector numbers
FB 227
1
All binector numbers
FB 228
1
st
nd
RESET, 2
All binector numbers
FB 230
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
rd
SET, 3
STORE).
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
11-137