Parameter list
PNU
Description
P804
Source for transmit data for G-SST3
*
Selection of connectors to be transferred as transmit data via basic
(G172)
converter interface 3
(G174)
When USS protocol (P800=2) is selected:
i001:
Selection for word 1
i002:
Selection for word 2
...
i016:
Selection for word 16
When peer-to-peer (P800=5) is selected:
i001:
Selection for word 1
i002:
Selection for word 2
...
i005:
Selection for word 5
i006:
Not used
...
i016:
Not used
Applicable settings:
0 = connector K0000
1 = connector K0001
etc.
P805
Options for G-SST3
i001:
0 = Bus terminator OFF
(G172)
1 = Bus terminator ON
(G174)
i002:
0 = Bit 10 of the 1
by PLC".
1 = Bit 10 of the 1
PLC", i.e. when bit 10 = 0, all other bits of the 1
as well as receive words 2 to 16, are not written to connectors
K9001 to K9016, or to binectors B9100 to B9915. All these
connectors and binectors retain their old values.
P806
USS bus address for G-SST3
*
This parameter is functional only when P800=2 (USS protocol). Address via
(G172)
which the unit can be addressed in USS bus operation.
11-88
st
receive word does not function as "Control
st
receive word does function as "Control by
Value range
[Unit]
Steps
All connector
numbers
1
0 to 1
1
st
receive word,
0 to 30
1
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 16
P052 = 3
FS=
P051 = 40
i001: 32
Offline
i002: 167
i003: 0
i004: 33
i005-i016: 0
Type: L2
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline