Siemens 6RA7086-6KS22 Operating Instructions Manual page 677

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
Binector
Name, description
B0143
Stat.word 2, bit 21 inverted
Stat.word 2, bit 22: 0=no overload alarm active, 1=overload alarm active
B0144
Stat.word 2, bit 22 inverted
B0145
B0146
Stat.word 2, bit 23: 0=no overtemperature fault active, 1=overtemperature fault active
B0147
Stat.word 2, bit 23 inverted
Stat.word 2, bit 24: 0=no overtemperature alarm active, 1=overtemperature alarm active
B0148
B0149
Stat.word 2, bit 24 inverted
B0150
Stat.word 2, bit 25: 0=no motor overtemperature alarm active, 1=motor overtemperature alarm active
Stat.word 2, bit 25 inverted
B0151
B0152
Stat.word 2, bit 26: 0=no motor overtemperature fault active, 1=motor overtemperature fault active
B0153
Stat.word 2, bit 26 inverted
Stat.word 2, bit 28: 0=no motor blocked fault active, 1=motor blocked fault active
B0156
Stat.word 2, bit 28 inverted
B0157
Messages
0=AUS1 or AUS3 active, 1=no AUS1 and no AUS3 is pending
B0160
B0161
B0160 inverted
B0164
1 = n < n
min
B0164 inverted
B0165
1 = Voltage at power section is active
B0166
B0167
B0166 inverted
B0168
1 = E-Stop is active
B0168 inverted
B0169
B0172
Output of "Setpoint-actual value deviation 2" signal
B0173
B0172 inverted
Acknowledgement of fault codes
B0179
Acknowledgement of control word or P key on PMU (pulse)
Motor interface
B0180
1 = Monitoring brush length (Terminal 211=0) has responded, condition for A025 or F025 fulfilled
B0181
1 = Monitoring bearing state (terminal 212=1) has responded, condition for A026 or F026 fulfilled
1 = Monitoring motor fan (terminal 213=0) has responded, condition for A027 or F027 fulfilled
B0182
1 = Monitoring motor temperature (terminal 213=0) has responded, condition for A028 or F028 fulfilled
B0183
Temperature sensor inputs
1=Alarm motor temperature 1
B0184
1=Alarm motor temperature 2
B0185
Alarms
1=Alarm A037 (I2t motor) is pending
B0186
1=Alarm A039 (I2t power section) is pending
B0187
B0188
1=Alarm A067 (heat sink temperature) is pending
1=Alarm A067 (device fan) is pending
B0189
Torque limitation, current limitation, current controller, armature gating unit
B0190
0 = pulsating current, 1 = continuous current
Speed limitation controller: Positive speed limit reached
B0192
Speed limitation controller: Negative speed limit reached
B0193
B0194
Current limitation: Positive current limit reached
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Connectors and binectors
Function
diag., Sheet
G183
G183
G183
G183
G183
G183
G183
G183
G183
G183
G183
G183
G183
G180
G180
G187
[SW 1.4 and later]
G187
[SW 1.4 and later]
[SW 1.4 and later]
[SW 1.4 and later]
G117
[SW 1.4 and later]
G117
[SW 1.4 and later]
[SW 1.9 and later]
G187
[SW 1.9 and later]
G187
G180
G186
G186
G186
G186
[SW 1.6 and later]
G185
G185
[SW 1.6 and later]
[SW 2.0 and later]
G162
[SW 1.8 and later]
G160
[SW 1.8 and later]
G160
[SW 1.8 and later]
G161
12-29

Hide quick links: