05.05
PNU
Description
P471
Source for manual/automatic switchover
*
Selection of binector to control "Manual/automatic switchover"
BDS
("0" state = manual).
(G126)
0 = binector B0000
1 = binector B0001
etc.
P472
Source for set motorized potentiometer
*
Selection of binector to control "Set motorized potentiometer"
BDS
("0" to "1" transition = set motorized potentiometer).
(G126)
0 = binector B0000
1 = binector B0001
etc.
P473
Storage of output value
*
0
No storage of output value:
FDS
The output is set to 0 in all operating states of >o5.
The starting point after ON is determined by P467 (MOP starting
(G126)
value).
1
Non-volatile storage of output value:
The output value remains stored in all operating states and after
voltage disconnection or failure. The last value stored is output
again after voltage recovery/reconnection.
11.26 Oscillation
Function:
Parameters P480 to P483 define the waveshape of a rectangular signal (oscillation setpoint K0203). The value set in P480 determines the
signal level for the time period set in P481 and the value set in P482 the signal level for the time period set in P483.
Oscillation: Selected in P485. The free-running rectangular signal is switched through to the output K0208.
P480
Oscillation setpoint 1
FDS
(G128)
P481
Oscillation time 1
FDS
(G128)
P482
Oscillation setpoint 2
FDS
(G128)
P483
Oscillation time 2
FDS
(G128)
P484
Source for standard setpoint
*
Selection of connector to be injected as the output value when the
FDS
"Oscillation" function is not selected
(G128)
0 = connector K0000
1 = connector K0001
etc.
P485
Source for oscillation selection
*
Selection of binector to control activation of the "Oscillation" function
BDS
(log. "1" state = oscillation active)
(G128)
0 = binector B0000
1 = binector B0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: 2
1
FS=0
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
0 to 1
Ind: 4
1
FS=0
Type: O2
-199.9 to 199.9
Ind: 4
[%]
FS=0,5
0.1% of maximum
Type: I2
speed
0.1 to 300.0
Ind: 4
[s]
FS=0.1
0.1s
Type: O2
-199.9 to 199.9
Ind: 4
[%]
FS=-0,4
0.1% of maximum
Type: I2
speed
0.1 to 300.0
Ind: 4
[s]
FS=0.1
0.1s
Type: O2
All connector
Ind: 4
numbers
FS=209
1
Type: L2
All binector numbers
Ind: 2
1
FS=0
Type: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
11-53