Siemens 6RA7086-6KS22 Operating Instructions Manual page 541

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
P714
Source for selection of sign reversal at "Analog selectable input 1"
*
Selection of binector to control sign reversal at the analog input ("1" state
= reverse sign)
(G113)
0 = binector B0000
1 = binector B0001
etc.
P715
Filtering time for "Analog selectable input 1"
Note: Hardware filtering of approximately 1 ms is applied as standard.
(G113)
P716
Source for enabling of "Analog selectable input 1"
*
Selection of binector to control enabling of the analog input ("1" state =
enabled)
(G113)
0 = binector B0000
1 = binector B0001
etc.
P717
Resolution of "Analog selectable input 1"
*
See P707
(G113)
Analog input terminals 8 / 9 (analog selectable input 2)
P721
Normalization of "Analog selectable input 2"
This parameter specifies the percentage value which is generated for an
FDS
input voltage of 10V (or an input current of 20mA) at the analog input.
(G114)
The following generally applies:
For voltage input:
[%] =
P
721
10
V
With current input:
[%] =
P
721
20
P722
Offset for "Analog selectable input 2"
(G114)
P723
Mode of signal injection at "Analog selectable input 2"
*
0 = Injection of signal with sign
1 = Injection of absolute value of signal
(G114)
2 = Injection of signal with sign, inverted
3 = Injection of absolute value of signal, inverted
P724
Source for selection of sign reversal at "Analog selectable input 2"
*
Selection of binector to control sign reversal at the analog input ("1" state
= reverse sign)
(G114)
0 = binector B0000
1 = binector B0001
etc.
P725
Filtering time for "Analog selectable input 2"
Note: Hardware filtering of approximately 1 ms is applied as standard.
(G114)
P726
Source for enabling of "Analog selectable input 2"
*
Selection of binector to control enabling of the analog input ("1" state =
enabled)
(G114)
0 = binector B0000
1 = binector B0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Y
X .. Input voltage in volts
X
Y .. % value which is generated for input
voltage X
Y
X .. Input current in mA
mA
X
Y .. % value which is generated for input
current X
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: None
1
FS=0
Type: L2
0 to 10000
Ind: None
[ms]
FS=0
1ms
Type: O2
All binector numbers
Ind: None
1
FS=1
Type: L2
10 to 14
Ind: None
[Bit]
FS=12
1 bit
Type: O2
-1000.0 to 1000.0
Ind: 4
[%]
FS=100.0
0.1%
Type: I2
-200.00 to 199.99
Ind: None
[%]
FS=0.00
0.01%
Type: I2
0 to 3
Ind: None
1
FS=0
Type: O2
All binector numbers
Ind: None
1
FS=0
Type: L2
0 to 10000
Ind: None
[ms]
FS=0
1ms
Type: O2
All binector numbers
Ind: None
1
FS=1
Type: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Online
P052 = 3
P051 = 40
Offline