Siemens 6SE7011-5EP60 Operating Instructions Manual
Siemens 6SE7011-5EP60 Operating Instructions Manual

Siemens 6SE7011-5EP60 Operating Instructions Manual

Simovert masterdrives vector control series frequency converter (ac-ac) compact plus type
Table of Contents

Advertisement

Aotewell Ltd
SIMOVERT MASTERDRIVES
Vector Control
Frequenzumrichter (AC-AC) Bauform Kompakt PLUS
Frequency Converter (AC-AC) Compact PLUS Type
Ausgabe / Edition: AB
HongKong|UK|China
www.aotewell.com
sales@aotewell.com
Industry Automation
Betriebsanleitung
Operating Instructions
Bestell-Nr. / Order No.: 6SE7087-6JP60
+86-755-8660-6182

Advertisement

Table of Contents
loading

Summary of Contents for Siemens 6SE7011-5EP60

  • Page 1 Aotewell Ltd www.aotewell.com Industry Automation SIMOVERT MASTERDRIVES Betriebsanleitung Operating Instructions Vector Control Frequenzumrichter (AC-AC) Bauform Kompakt PLUS Frequency Converter (AC-AC) Compact PLUS Type Ausgabe / Edition: AB Bestell-Nr. / Order No.: 6SE7087-6JP60 HongKong|UK|China sales@aotewell.com +86-755-8660-6182...
  • Page 2 However, the information in this document is regularly checked and necessary corrections will be included in subsequent editions. We are grateful for any recommendations for improvement. SIMOVERT Registered Trade Mark  Siemens AG 2001 All rights reserved HongKong|UK|China sales@aotewell.com +86-755-8660-6182...
  • Page 3: Table Of Contents

    Power connections for units with a width of 135 mm........7-8 7.1.3 Power connections for units with a width of 180 mm........7-10 Control connections ..................7-12 Conductor cross-sections, fuses, reactors............7-22 Combinations of units..................7-23 PARAMETERIZATION ..................8-1 Parameter menus....................8-1 Changeability of parameters ................8-5 Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 4: Table Of Contents

    Replacing the fan in units up to 180 mm wide ..........10-3 FORMING .......................11-1 TECHNICAL DATA ..................12-1 FAULTS AND ALARMS.................13-1 13.1 Faults.......................13-1 13.2 Alarms ......................13-18 13.3 Fatal errors (FF) ....................13-27 ENVIRONMENTAL FRIENDLINESS .............14-1 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 5: Definitions And Warnings

    NOTE For the purpose of this documentation, "Note" indicates important information about the product or about the respective part of the documentation which is essential to highlight. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 6: Contents

    Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser's purposes, the matter should be referred to the local SIEMENS sales office. The contents of this documentation shall not become part of or modify any prior or existing agreement, commitment or relationship.
  • Page 7 ♦ c = ESD shoes ♦ d = ESD overall ♦ e = ESD chain ♦ f = Cubicle ground connection Sitting Standing Standing / Sitting Fig. 1-1 ESD protective measures Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 8: Technical Data

    During operation, all covers and doors shall be kept The climatic conditions shall be in conformity with prEN closed. 50178. 7. Maintenance and servicing The manufacturer's documentation shall be followed. Keep these safety instructions in a safe place! 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 9: Description

    Motor V1/L2 V2/T2 connection W1/L3 W2/T3 Rectifier Precharging DC link Inverter C / L+ Braking D / L - resistor Brake chopper Fig. 2-1 Circuit principle of the frequency converter Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 10: Forming

    24 V supply or the line electronics power supply has been started, the unit voltage initializes itself. The action can take several seconds. The drive status is subsequently shown on the PMU. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 11 It is recommended not to couple the driven machine until the function test has been successfully completed. Further start-up and parameterization according to your specific requirements siehe "Ans 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 12 The units and components can be installed and commissioned after they have been unpacked and checked to ensure that everything is complete and that they are not damaged. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 13: Installation

    The units must only be operated in an ambient climate in accordance with DIN IEC 721-3-3 Class 3K3. For cooling air temperatures of more than 45 °C (113 °F) and installation altitudes higher than 1000 m, derating is required. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 14 220 mm 0.55 kW 1.1 / 1.5 kW 3.0 / 4.0 kW Side view Front view (without front panel) Fig. 5-2 Dimension drawings for housings up to 90 mm wide 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 15 135 mm 180 mm 220 mm 5.5 / 7.5 kW 11 / 15 kW Side view Front view Fig. 5-3 Dimension drawings for housings 135 mm and 180 mm wide Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 16: Installing The Optional Boards

    ♦ Remove the cover of the selected slot on the front panel. Removing the slot cover ♦ To do so, you must carefully cut through the four connecting points of the cover on the front panel with a thin knife. 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 17 Fig. 5-4 Position of the fixing screws on the right-hand side wall Slots for optional boards Slot A Slot B Slot C Fig. 5-5 Removing the right-hand side wall Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 18 Screw the optional board tight at the fastening points in the front section of the optional board ( Slot A Slot A Slot B Slot B Slot C Slot C Fig. 5-6 Installing the optional board 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 19: Installing Optional Boards On Units With A Width Of 135 Mm And 180 Mm

    ♦ At the power section, open the locking lever of the ribbon cable that connects up with the control electronics. ♦ Take off the front of the unit by moving it forwards. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 20 ♦ Screw the optional board tight at the fastening points in the front section of the optional board with the two screws ( Slot A Slot B Slot B Slot C Slot C Fig. 5-7 Installing the optional board 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 21 ♦ When the voltage has been switched in, the software of the unit recognizes which optional boards have been installed and you can then commence start-up. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 22 ♦ Eliminate any unnecessary cable lengths because these will produce additional coupling capacitances and inductances. ♦ Use cables with braided shields. Cables with foil shields have a shielding effect which is worse by a factor of five. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 23 ♦ IT networks in complex systems ♦ Applications in which the necessary dynamic operational behavior is limited on account of filter effects. This note must be particularly observed for option L20 (operation on non-grounded networks). 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 24: Connecting-Up

    ♦ Rated residual current of the residual-current protective device ≥ 300 mA ♦ Short motor cables (l < 20 m) ♦ No radio-interference suppression filter built in ♦ Only one converter connected per residual-current protective device Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 25 Terminal strip X102 Encoder connection X104 Motor connection X2 Shield connection Shield connection for motor cable for control cables Fig. 7-1 Connection overview for units up to 90 mm wide 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 26 Slot A X101 Terminal strip X101 Slot B X103 Terminal strip RS232/RS485 (USS) X103 X102 Encoder connection X104 Motor connection X2 Fig. 7-2 Connection overview for units 135 mm wide Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 27 (USS) S1 X101 Terminal strip X101 Slot B X103 Terminal strip RS232/RS485 (USS) X103 X102 Encoder connection X104 Motor connection X2 Fig. 7-3 Connection overview for units 180 mm wide 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 28: Power Connections

    Terminal U1 is at the front when installed. Table 7-1 Mains connection CAUTION The connector has to be screwed firmly to the housing (providing resistance to vibration and protecting against being inadvertently withdrawn). Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 29 The motor cables must be dimensioned in accordance with VDE 298, Part 2. After installation of the connector, the shield of the motor cable must be fixed to the shield plate through a large surface area. 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182...
  • Page 30 ♦ For reasons of protection, cables with 4 mm² Cu should be used at connection X6! CAUTION Length of connecting cable between converter and external brake resistor < 15 m. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 31: Power Connections For Units With A Width Of 135 Mm

    The motor cables must be dimensioned in accordance with VDE 298, Part 2. After installation of the connector, the shield of the motor cable must be fixed to the shield plate through a large surface area. 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182...
  • Page 32 ♦ For reasons of protection, cables with 4 mm² Cu should be used at connection X6! CAUTION Length of connecting cable between converter and external brake resistor < 15 m. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 33: Power Connections For Units With A Width Of 180 Mm

    The motor cables must be dimensioned in accordance with VDE 298, Part 2. After installation of the connector, the shield of the motor cable must be fixed to the shield plate through a large surface area. 6SE7087-6JP60 Siemens AG 7-10 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com...
  • Page 34 ♦ During pre-charging, the charging current of all connected capacitor modules flows via the terminals. ♦ For reasons of protection, cables with 4 mm Cu should be used at connection X7! Siemens AG 6SE7087-6JP60 7-11 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 35: Control Connections

    The external 24 V infeed and all circuits connected to the control terminals must meet the requirements for safety separation as stipulated in EN 50178 (PELV circuit = Protective Extra Low Voltage). 6SE7087-6JP60 Siemens AG 7-12 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com...
  • Page 36 Floating contact switch KTY84 or 30 V / 0.5 A PTC thermistor *) Type of fuse -F1: Miniature circuit-breaker 6 A characteristic C e. g. Siemens 5SX2 106-7 (see attached sheet) Fig. 7-4 Overview of the standard connections Siemens AG 6SE7087-6JP60...
  • Page 37 Connectable cross-section: 2.5 mm² (AWG 12) Terminal 33 is at the top when installed. Table 7-15 24 V voltage output, USS bus NOTICE The RS485 interface can be operated either via -X100 or -X103. 6SE7087-6JP60 Siemens AG 7-14 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 38 Terminal 1 is at the top when installed. Table 7-16 Control terminal strip In the case of digital inputs, levels below 3 V are interpreted as low and levels above 13 V as high. Siemens AG 6SE7087-6JP60 7-15 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 39 NO contact DC 30 V / max. 0.5 A (floating) Minimum load 7 mA Connectable cross-section: 0.14 mm to 1.5 mm (AWG 16) Table 7-17 Control terminal strip X102 6SE7087-6JP60 Siemens AG 7-16 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 40 ≤ 1.5 kΩ Plus (+ + + + ) terminal PTC: R + Temp cold KTY84/PTC Connectable cross-section: 0.14 mm to 1.5 mm (AWG 16) Table 7-19 Control terminal strip X104 Siemens AG 6SE7087-6JP60 7-17 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 41 Siemens. Siemens shall not be liable for recommendations that are made or implied as a result of the following description. No new warranty or liability claims over and above those stated in the Siemens general delivery conditions can be inferred from the following description.
  • Page 42 24 V supply must deliver at least 22 V at terminal X9:1/2 to ensure that the relay picks up reliably (internal voltage drop). Terminal strip - X533 Optocoupler / fibre optics supply Siemens AG 6SE7087-6JP60 7-19 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 43 X101.6 --> P654 = 120; P796 = 0 (comparison value) Fig. 7-5 Sample application of "safe stop" function with contactor safety combination for monitoring a moving protective device in Safety Category 3 to EN 954-1 6SE7087-6JP60 Siemens AG 7-20 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182...
  • Page 44 If contacts in the safety relay are sticking, the checkback contacts do not close and the safety combination on the right deenergizes main contactor K1 via delayed contacts 47/48 when the set delay period expires. Siemens AG 6SE7087-6JP60 7-21 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 45: Conductor Cross-Sections, Fuses, Reactors

    The dimensioning of the supply connection (conductor cross- section and fuse) is stated in Table 7-21 for use as a single drive. NOTE Both the cables and the semiconductors are protected by fuses with gR characteristics. 6SE7087-6JP60 Siemens AG 7-22 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182...
  • Page 46: Combinations Of Units

    24 V voltage output in the case of a converter with a housing width of 45 mm. To support the DC link circuit, a capacitor module can be connected to a Compact PLUS AC/AC converter. Siemens AG 6SE7087-6JP60 7-23 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 47: Parameterization

    It is possible for one parameter to belong to several menus. The parameter list indicates which individual menus a parameter belongs to. Assignment is effected via the menu number allocated to each menu. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 48 By entering a password in P359, access to the menus in the gray shaded area can be prohibited to unauthorized persons 1) only MASTERDRIVES Motion Control P358 Key P359 Lock Fig. 8-1 Parameter menus 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 49 Used to define the power section (only necessary for units of definition the Compact and chassis type) • When selected, the unit switches to status 0 "Power section definition" Table 8-1 Main menus Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 50 ♦ P358 key and ♦ P359 lock. 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 51: Changeability Of Parameters

    "Operation" (14) P222 Src n(act) cannot be changed on account of the drive status Table 8-3 Influence of drive status (r001) and parameter access (P053) on the changeability of a parameter Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 52: Parameter Input With Drivemonitor

    RS232 ↔ RS485 interface converter is necessary. On the device, an RS485 interface is integrated into the -X103 connection. For the cable: see pin assignment -X300 and device documentation of the interface converter. 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182...
  • Page 53: Drive Configuration Drivemonitor

    05.2003 Parameterization 8.3.2 Drive configuration DriveMonitor DriveMonitor starts with an empty drive window. Via the menu "Set up an ONLINE connection..." the USS bus can be scanned for connected devices: Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 54 Aotewell Ltd www.aotewell.com Industry Automation Parameterization 05.2003 The USS bus is scanned with the current baud rate. The baud rate can be changed via "Tools ONLINE Settings", see section 8.3.2.1. 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 55: Setting The Interface

    RS232/RS485. ♦ Tab card "Extended" Request retries and Response timeout; here you can increase the values already set if communication errors occur frequently. Fig. 8-4 Interface configuration Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 56: Drive Settings

    ♦ You must only specify the bus address of the drive during online operation (switchover with button Online/Offline) NOTE The specified bus address must be the same as that of the parameterized SST bus address in SIMOVERT MASTERDRIVES (P700). 6SE7087-6JP60 Siemens AG 8-10 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 57 If the value is changed, it must be/remain ensured that the setting value in the program matches the value in parameter P703 of the drive at all times. Fig. 8-6 Drive setting Siemens AG 6SE7087-6JP60 8-11 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 58 Aotewell Ltd www.aotewell.com Industry Automation Parameterization 05.2003 Drive Navigator Settings for Drive Navigator under Tools -> Options: Fig. 8-7 Drive Navigator 6SE7087-6JP60 Siemens AG 8-12 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 59 Direct to parameter list General diagnostics Download parameter file to drive Save drive parameters to a file Load standard application 1:1 device exchange Assisted F01 technology COMM Basic positioner operating screens Siemens AG 6SE7087-6JP60 8-13 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 60 Connection and device ok Connection ok, device in fault state Connection ok, device in alarm state Device is parameterized offline No connection with the device can be established (only offline parameterization possible). 6SE7087-6JP60 Siemens AG 8-14 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 61 Parameter Display of the current parameter value. You can change this by double- value clicking on it or selecting and pressing Enter. Physical dimension of the parameter, if there is one Siemens AG 6SE7087-6JP60 8-15 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 62: Faults And Alarms

    In each of these, only those parameters are displayed that are relevant for the faults and alarms and for messages and displays. You can change or monitor the parameters just like in any other parameter list. 6SE7087-6JP60 Siemens AG 8-16 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com...
  • Page 63: Alarms

    Seven-segment display for: Drive statuses Alarms and faults Parameter numbers Raise key Lower key Parameter indices Toggle key Parameter values Fig. 8-10 PMU in units of the Compact PLUS type Siemens AG 6SE7087-6JP60 8-17 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 64 4 figures (right-hand figure flashes if there are any further invisible figures to the right) Table 8-4 Operator control elements of the PMU (Compact PLUS type) 6SE7087-6JP60 Siemens AG 8-18 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182...
  • Page 65 Parameter changes made using the PMU are always safely stored in the EEPROM (protected in case of power failure) once the toggle key has been depressed. Siemens AG 6SE7087-6JP60 8-19 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 66 Set P060 to 0002 and select "Fixed settings" menu ä ä ä P060 P060 Select P970 ä P060 P970 Set P970 to 0000 and start parameter reset ∇ ∇ ∇ ∇ ä ä ä P970 °009 6SE7087-6JP60 Siemens AG 8-20 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 67: Parameter Input Via The Op1S

    Order numbers Components Order Number OP1S 6SE7090-0XX84-2FK0 Connecting cable 3 m 6SX7010-0AB03 Connecting cable 5 m 6SX7010-0AB05 Adapter for installation in cabinet door incl. 5 m cable 6SX7010-0AA00 Siemens AG 6SE7087-6JP60 8-21 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 68 OFF key Lower key Key for toggling between control levels Jog key 0 to 9: number keys Reset key (acknowledge) Reset Sign key Fig. 8-11 View of the OP1S 6SE7087-6JP60 Siemens AG 8-22 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 69: Connecting, Run-Up

    Plugging onto On the Compact PLUS rectifier unit, you can plug the OP1S onto the Compact PLUS Sub D socket X320 and lock it in place on the front cover. rectifier unit Siemens AG 6SE7087-6JP60 8-23 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 70: Run-Up

    OP1S without any further preparatory measures. When a bus system is started up with the OP1S, the slaves must first be configured individually. The plugs of the bus cable must be removed for this purpose. 6SE7087-6JP60 Siemens AG 8-24 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com...
  • Page 71: Parameterizing Steps

    Factory settings (parameter reset) (P060 = 2) (P060 = 8) Parameterizing with existing parameter files (download, P060 = 6) Parameterizing with parameter modules(quick parameterization, P060 = 3) Fig. 9-1 Detailed and quick parameterization Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 72: Parameter Reset To Factory Setting

    P970 = 0 0: Parameter reset 1: No parameter change Unit carries out parameter reset and then leaves the "Fixed settings" menu Fig. 9-2 Sequence for parameter reset to factory setting 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 73 All other factory setting values are not dependent on P366 and can be taken from the parameter list or from the block diagrams (in the Compendium). The factory settings for Index 1 (i001) of the respective parameter are displayed in the parameter list. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 74: Power Section Definition

    They must tally with the data given on the unit rating plate. PWE: Parameter value P070 In [A]: Rated output current in Ampere (P072) Order number In [A] 6SE7011-5EP60 6SE7013-0EP60 6SE7015-0EP60 6SE7018-0EP60 6SE7021-0EP60 10.0 6SE7021-4EP60 14.0...
  • Page 75: Parameterizing With Parameter Modules (Quick Parameterization, P060 = 3)

    Quick parameterization is effected in the "Download" converter status. Since quick parameterization includes the factory settings for all parameters, all previous parameter settings are lost. Quick parameterization incorporates an abridged drive setting, (e.g. pulse encoder always with pulse number/revolution 1024). Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 76 Enter the code number for the connected motor of type P097 = ? 1PH7(=1PA6)/1PL6/1PH4 (For list see Quick Parameterization) (Automatic parameter assignment is implemented as soon as the settings P095 = 2 and P097 > 0 have been made) 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 77 Enter the rated motor speed in rpm P108 = ? as per rating plate Enter the motor pole pair number P109 = ? (is automatically calculated) Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 78 (automatic factory setting according to P366) (followed by automatic parameterization as for P115 = 1) Return to the user menu P060 = 0 End of quick parameterization 6SE7087-6JP60 Siemens AG Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 79 P353 must be set accordingly (P352 is calculated automatically). If a rotational frequency in Hz is to be used as the reference (calculated using the pole pair number P109), P352 must be set. Siemens AG 6SE7087-6JP60 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 80 If this is not sufficient, you must change to the "Drive setting" menu (P060 = 5) to change the reference quantities. 6SE7087-6JP60 Siemens AG 9-10 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com...
  • Page 81 A080 appear. WARNING During motor identification inverter pulses are released and the drive rotates! For reasons of safety, identification should first be carried out without coupling of the load. Siemens AG 6SE7087-6JP60 9-11 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 82 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 6SE7087-6JP60 Siemens AG 9-12 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 83 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps Siemens AG 6SE7087-6JP60 9-13 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 84 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 6SE7087-6JP60 Siemens AG 9-14 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 85 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps ===•==•==•==•==• ===•==•==•==•==• • • Siemens AG 6SE7087-6JP60 9-15 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 86 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 ===•==•==•==•==• ===•==•==•==•==• • • 6SE7087-6JP60 Siemens AG 9-16 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 87 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps Siemens AG 6SE7087-6JP60 9-17 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 88 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 ===•==•==•==•==• ===•==•==•==•==• • • 6SE7087-6JP60 Siemens AG 9-18 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 89 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps •==•==•==•==•==• •==•==•==•==• Siemens AG 6SE7087-6JP60 9-19 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 90 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 6SE7087-6JP60 Siemens AG 9-20 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 91 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps Siemens AG 6SE7087-6JP60 9-21 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 92 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 6SE7087-6JP60 Siemens AG 9-22 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 93 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps Siemens AG 6SE7087-6JP60 9-23 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 94 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 6SE7087-6JP60 Siemens AG 9-24 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 95 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps Siemens AG 6SE7087-6JP60 9-25 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 96 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 6SE7087-6JP60 Siemens AG 9-26 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 97 Aotewell Ltd www.aotewell.com Industry Automation 05.2003 Parameterizing Steps Siemens AG 6SE7087-6JP60 9-27 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 98 Aotewell Ltd www.aotewell.com Industry Automation Parameterizing Steps 05.2003 6SE7087-6JP60 Siemens AG 9-28 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 99: Maintenance

    ≥ 35,000 hours and an The fan is designed for a service life of L ambient temperature of = 45 °C. It must be exchanged in good time to ensure the availability of the unit. Siemens AG 6SE7087-6JP60 10-1 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 100: Replacing The Fan In Units Up To 45 Mm Wide

    DANGER Make sure that the leads to the fan are connected the right way round. Otherwise the fan will not operate! 6SE7087-6JP60 Siemens AG 10-2 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com...
  • Page 101: Replacing The Fan In Units 135 Mm Wide

    Internal fan DANGER Before removing the old fan and fitting a new one, make sure that the inverter is disconnected from the power supply. Siemens AG 6SE7087-6JP60 10-3 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 102 ♦ Make sure that the arrow indicating the direction of air flow points to the inside of the unit. DANGER Make sure that the leads to the fan are connected the right way round. Otherwise the fan will not operate! 6SE7087-6JP60 Siemens AG 10-4 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182...
  • Page 103 Manufacture took place in December 2001. During forming a defined voltage and a limited current are applied to the DC link capacitors and the internal conditions necessary for the function of the DC link capacitors are restored again. Siemens AG 6SE7087-6JP60 11-1 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 104 ♦ Energize the forming circuit. The duration of forming depends on the idle time of the converter. Forming time in hours Off-circuit idle time in years Fig. 11-2 Forming time as a function of converter idle time 6SE7087-6JP60 Siemens AG 11-2 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 105 Standard No radio interference suppression • Options Radio interference suppression filter for class B1 or A1 to EN 55011 Noise immunity Industrial sector to EN 61800-3 Paint Indoor duty Siemens AG 6SE7087-6JP60 12-1 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 106 According to DIN IEC 68-2-27 / 08.89 30 g, 16 ms half-sine shock - Drop According to DIN IEC 68-2-31 / 04.84 onto a surface and onto an edge Table 12-1 General data 6SE7087-6JP60 Siemens AG 12-2 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 107 Sound pressure levels, types of construction, dimensions, weights Sound pressure level [dB(A)] Dimensions [mm] • Width 67.5 67.5 • Height • Depth Weight approx. [kg] Table 12-2 Technical data of converter (Part 1) Siemens AG 6SE7087-6JP60 12-3 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 108 Sound pressure levels, types of construction, dimensions, weights Sound pressure level [dB(A)] Dimensions [mm] • Width • Height • Depth Weight approx. [kg] 10.8 10.9 14.7 14.9 Table 12-3 Technical data of converter (Part 2) 6SE7087-6JP60 Siemens AG 12-4 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 109 P20 power P3 at power PDB resistor R min current at R min R min at R min [kW] [Ω] [kW] [kW] [kW] 0.55 6SE7011-5EP60 1.25 6SE7013-0EP60 1.25 6SE7015-0EP60 1.25 6SE7018-0EP60 10.0 6SE7021-0EP60 14.0 6SE7021-4EP60 20.5 6SE7022-1EP60 27.0 6SE7022-7EP60 34.0...
  • Page 110 P586 = 12 P586 = 14 P586 = 16 P586 = 18 P586 = 20 -102.19 P586 = 22 Fig. 12-1 Converter with external braking resistor and fault trip via thermoswitch 6SE7087-6JP60 Siemens AG 12-6 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 111 K 0.80 1.125 1.25 * 1.375 * 1.5 * *See note below Coolant temperature in °C Permissible rated current in % 16 18 Pulse frequency Fig. 12-2 Derating curves Siemens AG 6SE7087-6JP60 12-7 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 112 Character Month of manufacture 2001 1 to 9 January to September 2002 October 2003 November 2004 December Table 12-4 Assignment of characters to the month and year of manufacture 6SE7087-6JP60 Siemens AG 12-8 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 113 Slot A Slot B Slot B CBP2: PROFIBUS EB2: Expansion Board 2 Slot A Slot A Slot B Slot B “Safe Stop” option Table 12-5 Meaning of the option codes Siemens AG 6SE7087-6JP60 12-9 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 114 = 2: Overvoltage in the DC link of the slave. P071 beforehand) - Reduce P526 Fly Search Speed. - Reduce P259 Max Regen Power (only for P100 = 3, 4 or 5) Siemens AG 6SE7087-6JP60 13-1 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 115 25 % of the motor no- Check the motor cable I too low load current. Note: Only for U800 = 1 Irrespective of the type of control (Difference to F012) 6SE7087-6JP60 Siemens AG 13-2 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 116 Jumper applied for SAFE STOP? power supply during operation (only for SAFE STOP checkback connected? SAFE STOP Compact PLUS units) On Compact PLUS units: check 24 V supply Compact PLUS only Siemens AG 6SE7087-6JP60 13-3 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 117 (-X2:U2 - including motor) - that CU is correctly inserted - that the switch for "SAFE STOP" (X9/5-6) is open (only for units with order No..-11, ...-21,...-31, ...-61). 6SE7087-6JP60 Siemens AG 13-4 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 118 During a parameter task, a voltage failure has Re-enter the parameter. The number of the occurred on the board. parameter concerned can be seen in fault Voltage OFF during value r949. parameter storage Siemens AG 6SE7087-6JP60 13-5 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 119 - P109 Motor #PolePairs The product of P109 and P138 must be smaller than 19200. Check or replace tachometer. Check connection to tachometer. - Replace CU, or replace the unit (Compact PLUS) 6SE7087-6JP60 Siemens AG 13-6 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 120 Correct this Parameter fault after parameter (ALL indices) and switch voltage off factory setting/init. and on again. Several parameters may be affected, i.e. repeat process. Siemens AG 6SE7087-6JP60 13-7 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182...
  • Page 121 MLFB. Counter-measure: - Check ImPI or communications card and replace, if necessary. - Check configuration of multi-parallel circuit. - Check parameterization. - Replace CU - Replace ImPI. 6SE7087-6JP60 Siemens AG 13-8 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 122 4 mA at analog input 3, slave 2 fallen short of Check the connection of the signal source to the SCI1 (slave 2) -X428: 10, 11. AnInp3 SL2 not Compact PLUS Siemens AG 6SE7087-6JP60 13-9 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 123 Power down and power up again. If it a parameter from the standstill measurement reoccurs, replace CU, or replace the unit Mld Param. or the rotating measurement (Mot ID). (Compact PLUS) 6SE7087-6JP60 Siemens AG 13-10 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 124 7 Incorrect gain generates the "no signal" message) 8 Incorrect pulse number Checking the measurement cables. Checking the parameters - P130 Src Speed ActV - P1151 Encoder Pulse # Siemens AG 6SE7087-6JP60 13-11 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 125 1) In phase V there is a ground fault or a defective valve (always conductive) or the "SAFE STOP" switch (X9/5-6) is open (only for units with Order No..-11, ...-21, ...-31). 6SE7087-6JP60 Siemens AG 13-12 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com...
  • Page 126 Dev. Dead-time compensation (1, 2, 3 as above) X O O O O Dev. Valve voltage (1, 2, 3 as above) The motor, power section or actual-value sensing are significantly non-symmetrical. Siemens AG 6SE7087-6JP60 13-13 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 127 See TB documentation Technology board fault not Compact PLUS F121 See TB documentation Technology board fault not Compact PLUS F122 See TB documentation Technology board fault not Compact PLUS 6SE7087-6JP60 Siemens AG 13-14 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 128 See TB documentation Technology board fault not Compact PLUS F132 See TB documentation Technology board fault not Compact PLUS F133 See TB documentation Technology board fault not Compact PLUS Siemens AG 6SE7087-6JP60 13-15 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 129 See TB documentation Technology board fault not Compact PLUS F143 See TB documentation Technology board fault not Compact PLUS F144 See TB documentation Technology board fault not Compact PLUS 6SE7087-6JP60 Siemens AG 13-16 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 130 Switch off the unit and switch it on again. If the fault re-occurs, replace CU, or replace the unit Fault in EEPROM (Compact PLUS) Table 13-1 Fault numbers, causes and their counter-measures Siemens AG 6SE7087-6JP60 13-17 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 131 - Are the motor and the converter matched? - Have the dynamic performance requirements been exceeded. A021 An overvoltage condition has occurred. Check the supply voltage. The converter regenerates without regeneration possibility. Overvoltage 6SE7087-6JP60 Siemens AG 13-18 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 132 REV Spd is (are) interrupted or released (both control word bits are zero) A036 The brake checkback indicates the "Brake still Check brake checkback (see FD 470) closed" state. Brake checkback "Brake still closed" Siemens AG 6SE7087-6JP60 13-19 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 133 - If there is a signal fault, use the DTI board if necessary. If required, change P215. - Additionally for synchronous motors (P095=12): Do not grant inverter release until the motor is at standstill 6SE7087-6JP60 Siemens AG 13-20 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 134 Check cause of alarm (see FD 710) (1). Alarm 1 Function blocks A062 An active signal is present at binector U066 Check cause of alarm (see FD 710) (1). Alarm 2 Function blocks Siemens AG 6SE7087-6JP60 13-21 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 135 The measured resistance has been limited to Converter output and motor output are too the maximum value of 49%. different. r-g limit Check motor data input P095 to P109. 6SE7087-6JP60 Siemens AG 13-22 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 136 The following description refers to the 1st CBP. For other CBs or the TB see the CB alarm operating instructions for the CB board. The CBP does not generate this alarm! Siemens AG 6SE7087-6JP60 13-23 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com...
  • Page 137 Compact PLUS A100 See user manual for TB board TB alarm 1 not Compact PLUS A101 See user manual for TB board TB alarm 1 not Compact PLUS 6SE7087-6JP60 Siemens AG 13-24 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 138 Compact PLUS A113 See user manual for TB board TB alarm 2 not Compact PLUS A114 See user manual for TB board TB alarm 2 not Compact PLUS Siemens AG 6SE7087-6JP60 13-25 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 139 See user manual for TB board TB alarm 2 not Compact PLUS A128 See user manual for TB board TB alarm 2 not Compact PLUS Table 13-2 Alarm numbers, causes and their counter-measures 6SE7087-6JP60 Siemens AG 13-26 Operating Instructions SIMOVERT MASTERDRIVES sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 140: Fatal Errors (Ff)

    (During processing of the fatal errors, a fault number has occurred which is unknown to date). FF15 Stack overflow (C-Compiler Stack) Replace the board CSTACK_OVERFLOW Table 13-3 Fatal errors Siemens AG 6SE7087-6JP60 13-27 SIMOVERT MASTERDRIVES Operating Instructions sales@aotewell.com +86-755-8660-6182 HongKong|UK|China...
  • Page 141: Environmental Friendliness

    Special significance was placed on the reduction of the volume, weight and variety of metal and plastic components. Plastics ABS: PMU board, Siemens logo components used PC / ABS: Front cover VC Large PA6: Front cover VC, terminal strips, spacer bolts, fan impeller PA6.6:...
  • Page 142 10.2001 Environmental Friendliness reviewed edition 05.2003 Group: Automation and Drives (A&D) Division: Variable-Speed Drive Systems Postfach 3269, D-91050 Erlangen Siemens Aktiengesellschaft Subject to change Order No.: 6SE7087-6JP60 Printed in the Federal Republic of Germany 05.2003 HongKong|UK|China sales@aotewell.com +86-755-8660-6182...

Table of Contents