Siemens 6RA7086-6KS22 Operating Instructions Manual page 473

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
r012
Motor temperature
Display of motor temperature when a KTY 84 temperature sensor is
(G185)
connected (P490.x=1).
A value of "0" is always output in r012 when a PTC thermistor or no
temperature sensor is installed.
i001:
Motor temperature 1 (sensor at terminals 22 / 23)
i002:
Motor temperature 2 (sensor at terminals 204 / 205)
r013
Heatsink temperature
Display of heatsink temperature
r014
Temperature rise
i001:
Calculated motor temperature rise (see P114)
i002:
Calculated thyristor temperature rise (see P075)
r015
Display of line voltage (armature)
(generated as arithmetic rectification average, RMS value display applies to
sinusoidal voltage, average over 3 line-to-line voltages)
r016
Display of line voltage (field)
(generated as arithmetic rectification average, RMS value display applies to
sinusoidal voltage)
r017
Display of line frequency
r018
Display of firing angle (armature)
(G163)
r019
Display of actual armature current
The internal actual armature current value is displayed (arithmetic average
(G162)
over the last 6 current peaks in each case)
r020
Display of the absolute value of armature current setpoint
(G162)
r021
Display of torque setpoint after torque limitation
∧ 0.1% of rated motor torque (=rated motor armature current
=
Steps: 1
(G160)
(P100) * magnetic flux at rated motor field current (P102))
r022
Display of torque setpoint before torque limitation
∧ 0.1% of rated motor torque (=rated motor armature current
=
Steps: 1
(G160)
(P100) * magnetic flux at rated motor field current (P102))
r023
Display of speed controller setpoint/actual value deviation
(G152)
r024
Display of actual speed value from pulse encoder
(G145)
r025
Display of actual speed controller value
(G151)
r026
Display of speed controller setpoint
(G152)
r027
Display of ramp-function generator output
(G136)
r028
Display of ramp-function generator input
(G136)
r029
Display of main setpoint before limitation
(G135)
r034
Display of firing angle (field)
(G166)
r035
Display of field current controller actual value
(G166)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
-58 to +318
Ind: 2
[°C]
Type: I2
1°C
-47 to +200
Ind: None
[°C]
Type: I2
1°C
0.0 to 200.0
Ind: 2
[%]
Type: O2
0.1%
0.0 to 2800.0
Ind: None
[V]
Type: O2
0.1V
0.0 to 800.0
Ind: None
[V]
Type: O2
0.1V
0.00 to 120.00
Ind: None
[Hz]
Type: O2
0.01Hz
0.00 to 180.00
Ind: None
[degrees]
Type: O2
0.01degrees
-400.0 to 400.0
Ind: None
[% of P100]
Type: I2
0.1% of P100
0.0 to 300.0
Ind: None
[% of P100]
Type: I2
0.1% of P100
-400.0 to 400.0
Ind: None
[%]
Type: I2
0.1% (see column on
left)
-400.0 to 400.0
Ind: None
[%]
Type: I2
0.1% (see column on
left)
-200.00 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.00 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.00 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.00 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.00 to 199.99
Ind: None
[%]
Type: I2
0.01%
0.00 to 180.00
Ind: None
[degrees]
Type: O2
0.01degrees
0.0 to 199.9
Ind: None
[% of P102]
Type: O2
0.1% of P102
Parameter list
See
Change
(Access /
Status)
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
11-9