Siemens 6RA7086-6KS22 Operating Instructions Manual page 615

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
U554
Filtering time
(2554)
i001:
Filtering time derivative/delay element 1
S00
i002:
Filtering time derivative/delay element 2
i003:
Filtering time derivative/delay element 3
(B156)
i004:
Filtering time derivative/delay element 4
(B157)
i005:
Filtering time derivative/delay element 5
(B158)
i006:
Filtering time derivative/delay element 6
i007:
Filtering time derivative/delay element 7
i008:
Filtering time derivative/delay element 8
i009:
Filtering time derivative/delay element 9
i010:
Filtering time derivative/delay element 10
11.75 Commutation monitoring
n560
Parameters for SIMOREG CCP
n569
n570
n571
n572
n574
n575
n576
U577
U578
U580
Control word for commutation monitoring
(2580)
The commutation of the converter is constantly monitored. If a commutation
failure is detected, fault message F030 is activated and the thyristor is
quenched by the SIMOREG CCP (if installed).
Detection of a commutation failure is based on three decision criteria. They
can be individually activated/deactivated with this parameter for test
purposes.
0:
None of the three decision criteria are evaluated
1:
Decision criterion 1 (sufficient voltage time area for
commutation) is evaluated
2:
Decision criterion 2 (curvature of the current crest curve) is
evaluated
4:
Decision criterion 3 (maximum current actual value) is evaluated
Setting instruction:
Each decision criterion has a numeric code.
If more than one decision criterion is to be evaluated, the sum of the
relevant digits must be entered.
U581
Diagnostic memory for commutation monitoring
(2581)
This memory is updated every time fault message F030 is activated.
It provides the SIEMENS specialist with more detailed information about the
cause of the commutation failure.
U582
Reaction of commutation monitor
(2582)
This parameter allows the reaction of the commutation monitor to be
programmed.
1
Detection of a commutation failure or overcurrent results in
immediate pulse blocking and generation of warning A030. The
pulses are enabled again after approximately 20ms and warning
A030 is reset.
2
Detection of a commutation failure or overcurrent results in
immediate pulse blocking and generation of fault message
F030.
Important:
The setting U582 = 1 is not allowed when the SIMOREG CCP is selected
(P790 = 6)!
Parameter for SIMOREG CCP
U583
(2583)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
[SW 1.8 and later]
0 to 10000
[ms]
(FB 270)
1
(FB 271)
(FB 272)
(FB 273)
(FB 274)
(FB 275)
(FB 276)
(FB 277)
(FB 278)
(FB 279)
0 to 7
[SW 2.1 and later]
1
0 to 65535
[SW 2.1 and later]
1
1 to 2
[SW 2.1 and later]
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 10
P052 = 3
FS=100
P051 = 40
Type: O2
on-line
Ind: none
P052 = 3
FS=7
P051 = 40
Type: O2
online
Ind: 68
P052 = 3
FS=0
P051 = 40
Type: O2
online
Ind: none
P052 = 3
FS=2
P051 = 40
Type: O2
online
11-151