Siemens 6RA7086-6KS22 Operating Instructions Manual page 588

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

Parameter list
PNU
Description
Characteristic blocks
The curve of the characteristics can be defined by 10 points each:
Index i001 to i010 of the parameters for the x values (U282, U285, U288): x values for FB 106, FB 107, FB 108
Index i001 to i010 of the parameters for the y values (U283, U286, U289): associated y values
SW1.8 and later:
Index i011 to i020 of the parameters for the x values (U282, U285, U288): x values for FB 280, FB 282, FB 284
Index i011 to i020 of the parameters for the y values (U283, U286, U289): associated y values
Index i021 to i030 of the parameters for the x values (U282, U285, U288): x values for FB 281, FB 283, FB 285
Index i021 to i030 of the parameters for the y values (U283, U286, U289): associated y values
for x = -200.00% up to x value acc. to index i001 (or i011 or i021) of the parameter for the x values gilt:
y = value acc. to index i001 (or i011 or i021) of the parameter for the y values
for x = x value acc. to index i010 (or i020 or i030) of the parameter for the x values to x = 200.00% gilt:
y = value acc. to index i010 (or i020 or i030) of the parameter for the y values
The distance between two adjacent x or y values must not be more than 199.99% otherwise deviations from the required shape of the
characteristic can
Characteristic block 1 (output = K9229)
Characteristic block 4 (output = K9410) [SW1.8 and later]
Characteristic block 5 (output = K9411) [SW1.8 and later]
U281
Source for input quantity
(2281)
0 = Connector K0000
*
1 = Connector K0001
S00
etc.
(B160)
Up to SW 1.7:
Selected connector = input quantity for FB106
SW 1.8 and later:
i001
Input quantity
i002
Input quantity
i003
Input quantity
U282
x values
(2282)
i001
1st characteristic point
S00
i002
2nd characteristic point
...
(B160)
i010
10th characteristic point
SW 1.8 and later:
i011
1st characteristic point
i012
2nd characteristic point
...
i020
10th characteristic point
i021
1st characteristic point
i022
2nd characteristic point
...
i030
10th characteristic point
U283
y values
(2283)
i001
1st characteristic point
S00
i002
2nd characteristic point
...
(B160)
i010
10th characteristic point
SW 1.8 and later:
i011
1st characteristic point
i012
2nd characteristic point
...
i020
10th characteristic point
i021
1st characteristic point
i022
2nd characteristic point
...
i030
10th characteristic point
11-124
for FB106
for FB280
for FB281
for FB106
for FB106
for FB106
for FB280
for FB280
for FB280
for FB281
for FB281
for FB281
for FB106
for FB106
for FB106
for FB280
for FB280
for FB280
for FB281
for FB281
for FB281
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All connector
Ind: 3
numbers
FS=0
1
Type: L2
-200.00 to 199.99
Ind:30
[%]
FS=0.00
0.01
Type: I2
-200.00 to 199.99
Ind: 30
[%]
FS=0.00
0.01
Type: I2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
FB 106
FB 280
FB 281
P052 = 3
P051 = 40
off-line
P052 = 3
P051 = 40
on-line
P052 = 3
P051 = 40
on-line
6RX1700-0AD76