Siemens 6RA7086-6KS22 Operating Instructions Manual page 471

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
o13
Software update in progress
o13.0
Waiting for arrival of start command from HEXLOAD PC routine
(press the DOWN key to abort this status and start a RESET)
o13.1
Deletion of Flash EPROM in progress
xxxxx
Display of address currently being programmed
o13.2
The Flash EPROM has been successfully programmed
(a RESET is performed automatically after approx. 1 second)
o13.3
Programming of the Flash EPROM has failed
(press UP key to return to operating state o13.0)
o14
Loading of boot sector in progress
(this operation is performed only in factory)
o15
Electronics not connected to voltage
Dark display: Waiting for voltage at terminals 5U1, 5W1
(electronics supply voltage).
11.2
General visualization parameters
r001
Display of terminals 4 and 5 (main setpoint)
(G113)
r002
Analog input, terminals 103 and 104 (main actual value)
(G113)
r003
Analog input, terminals 6 and 7 (selectable input 1)
(G113)
r004
Analog input, terminals 8 and 9 (selectable input 2)
(G114)
r005
Analog input, terminals 10 and 11 (selectable input 3)
(G114)
r006
Analog output, terminals 14 and 15
Display of output value before normalization and offset
(G115)
r007
Analog output, terminals 16 and 17
Display of output value before normalization and offset
(G115)
r008
Analog output, terminals 18 and 19
Display of output value before normalization and offset
(G116)
r009
Analog output, terminals 20 and 21
Display of output value before normalization and offset
(G116)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
-200.0 to 199.99
Ind: None
[%]
Type: I2
0.01%
Parameter list
See
Change
(Access /
Status)
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
11-7