Parameter list
PNU
Description
U223
Source for control signals RESET, TRACK and STORE
(2223)
i001:
TRACK
*
i002:
STORE
S00
i003:
RESET
(B145)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U224
Control word for Power On Mode
(2224)
0
Volatile storage:
*
Zero appears at output when voltage recovers
S00
1
Non-volatile storage:
When the voltage is disconnected or fails, the current output
(B145)
value is stored and then output when the voltage recovers/is
reconnected
Tracking/storage element 2
U225
Source for input quantity (x)
(2225)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B145)
U226
Source for control signals RESET, TRACK and STORE
(2226)
i001:
TRACK
*
i002:
STORE
S00
i003:
RESET
(B145)
Settings:
0 = binector B0000
1 = binector B0001
etc.
U227
Control word for Power On Mode
(2227)
0
Volatile storage:
*
Zero appears at output when voltage recovers
S00
1
Non-volatile storage:
When the voltage is disconnected or fails, the current output
(B145)
value is stored and then output when the voltage recovers/is
reconnected
Connector memories
The connector memories are memory elements for the input quantities selected via the parameters. The outputs are linked to connectors.
While the SET input is in the log. "1" state, output quantity y tracks input quantity x continuously. If the SET input changes state from log.
"1" to log. "0", the current value of x is stored and output continuously at y.
Output (y) = 0 is set on POWER ON.
Connector memory 1
U228
Source for input quantity (x)
(2228)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B145)
U229
Source for control signal SET
(2229)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B145)
Connector memory 2
U230
Source for input quantity (x)
(2230)
0 = connector K0000
*
1 = connector K0001
S00
etc.
(B145)
U231
Source for control signal SET
(2231)
0 = binector B0000
*
1 = binector B0001
S00
etc.
(B145)
11-118
Value range
[Unit]
Steps
All binector numbers
FB 82
1
0 to 1
FB 82
1
All connector
FB 83
numbers
1
All binector numbers
FB 83
1
0 to 1
FB 83
1
All connector
FB 84
numbers
1
All binector numbers
FB 84
1
All connector
FB 85
numbers
1
All binector numbers
FB 85
1
SIEMENS AG
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: O2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
6RX1700-0AD76
Operating Instructions

Hide quick links:

Advertisement

Table of Contents
loading