05.05
PNU
Description
Source for input signal, inverter 8 (output = B9457)
U387
(2387)
As for U380
*
S00
(B207)
Source for input signal, inverter 9 (output = B9458)
U388
(2388)
As for U380
*
S00
(B207)
Source for input signal, inverter 10 (output = B9459)
U389
(2389)
As for U380
*
S00
(B207)
Source for input signal, inverter 11 (output = B9460)
U390
(2390)
As for U380
*
S00
(B207)
Source for input signal, inverter 12 (output = B9461)
U391
(2391)
As for U380
*
S00
(B207)
Source for input signal, inverter 13 (output = B9462)
U392
(2392)
As for U380
*
S00
(B207)
Source for input signal, inverter 14 (output = B9463)
U393
(2393)
As for U380
*
S00
(B207)
Source for input signal, inverter 15 (output = B9464)
U394
(2394)
As for U380
*
S00
(B207)
Source for input signal, inverter 16 (output = B9465)
U395
(2395)
As for U380
*
S00
(B207)
NAND elements with 3 inputs each
The input signals selected via the 3 indices of the parameter are combined in an NAND operation and the result applied to the specified
binector.
Source for input signals, NAND element 1 (output = B9470)
U400
(2400)
i001
Source for input 1
*
i002
Source for input 2
S00
i003
Source for input 3
(B207)
Settings:
0 = binector B0000
1 = binector B0001
etc.
Source for input signals, NAND element 2 (output = B9471)
U401
(2401)
As for U400
*
S00
(B207)
Source for input signals, NAND element 3 (output = B9472)
U402
(2402)
As for U400
*
S00
(B207)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
All binector numbers
FB 187
1
All binector numbers
FB 188
1
All binector numbers
FB 189
1
All binector numbers
FB 190
1
All binector numbers
FB 191
1
All binector numbers
FB 192
1
All binector numbers
FB 193
1
All binector numbers
FB 194
1
All binector numbers
FB 195
1
All binector numbers
FB 200
1
All binector numbers
FB 201
1
All binector numbers
FB 202
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 3
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
11-135

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents