Siemens 6RA7086-6KS22 Operating Instructions Manual page 577

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
U177
Source for input signal and limits for limiter 2
(2177)
Output = connector K9170
*
i001:
Input signal
S00
i002:
Upper limiting value (L+)
(B134)
i003:
Lower limiting value (L-)
(B135)
Source for input signal and limits for limiter 5
Output = connector K9179
i004:
Input signal
i005:
Upper limiting value (L+)
i006:
Lower limiting value (L-)
Settings:
0 = connector K0000
1 = connector K0001
etc.
U178
Limit value for limiter
(2178)
i001:
Applied to connector K9168 (FB 66)
S00
i002:
Applied to connector K9177 (FB 213)
(B134)
(B135)
U179
Source for input signal and limits for limiter 3
(2179)
Output = connector K9173
*
i001:
Input signal
S00
i002:
Upper limiting value (L+)
(B134)
i003:
Lower limiting value (L-)
(B135)
Source for input signal and limits for limiter 6
Output = connector K9262
i004:
Input signal
i005:
Upper limiting value (L+)
i006:
Lower limiting value (L-)
Settings:
0 = connector K0000
1 = connector K0001
etc.
U180
Limit value for limiter
(2180)
i001:
Applied to connector K9171 (FB 67)
S00
i002:
Applied to connector K9260 (FB 214)
(B134)
(B135)
Limit-value monitors for double word connectors
U181
Source for input signal (A) and operating threshold (B)
(2181)
st
for 1
limit-value monitor for double word connectors
*
nd
for 2
limit-value monitor for double word connectors
S00
i001:
Input signal for 1
(B151)
i002:
Operating threshold for 1
i003:
Input signal for 2
i004:
Operating threshold for 2
Settings:
0 = connector K0000
1 = connector K0001
etc.
U182
Hysteresis for 1
(2182)
Hysteresis for 2
S00
(B151)
i001:
Hysteresis for 1
i002:
Hysteresis for 2
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
st
limit-value monitor
st
limit-value monitor
nd
limit-value monitor
nd
limit-value monitor
st
limit-value monitor for double word connectors FB 68
nd
limit-value monitor for double word connectors FB69
st
limit-value monitor
nd
limit-value monitor
Value range
[Unit]
Steps
All connector
FB 66
numbers
1
FB 213
[SW2.0 and later]
-199.99 to 199.99
FB 66, FB213
[%]
0.01%
[SW2.0 and later]
All connector
FB 67
numbers
1
FB 214
[SW2.0 and later]
-199.99 to 199.99
FB 67, FB214
[%]
0.01%
[SW2.0 and later]
All connector
numbers
FB 68
1
FB 69
[SW 1.9 and later]
0.00 to 100.00
[%]
0.01%
[SW 1.9 and later]
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 6
P052 = 3
FS=
P051 = 40
i001: 0
Offline
i002: 9168
i003: 9169
i004: 0
i005: 9177
i006: 9178
Type: L2
Ind: 2
P052 = 3
FS=100.00
P051 = 40
Type: I2
Offline
Ind: 6
P052 = 3
FS=
P051 = 40
i001: 0
Offline
i002: 9171
i003: 9172
i004: 0
i005: 9260
i006: 9261
Type: L2
Ind: 2
P052 = 3
FS=100.00
P051 = 40
Type: I2
Offline
Ind: 4
P052 = 3
FS=0
P051 = 40
Type: L2
off-line
Ind: 2
P052 = 3
FS=0.00
P051 = 40
Type: O2
off-line
11-113