Parameter list
PNU
Description
U007
Numbers of the user parameters
(2007)
Parameters for entering the numbers of those parameters that are to be
*
accessible if the key and lock are set differently.
NOTE:
Parameters U000 to U999 must be entered as 2000 to 2999
11.53 Processor utilization
n009
Processor utilization
(2009)
This parameter is particularly relevant as regards the selection of function
blocks of technology software in the basic unit (option S00) and the
definition of the time slices in which these function blocks are processed
(see also Section 8, Function Diagram B101 and parameters U950 to
U952).
i001:
Current total processor utilization (=K9990)
i002:
Extrapolated total processor utilization for line frequency = 65Hz
(=K9991)
i003:
Current total processor utilization by programs in
time slice 10 (=K9992)
i004:
Current total processor utilization by programs in
time slice 4 (=K9993)
i005:
Current total processor utilization by programs in
time slice 2 (=K9994)
i006:
Current total processor utilization by programs in
time slice 1 (=K9995)
11.54 Display parameters for technology functions with S00
Only active with optional technology software S00
Connector/binector converters
Connector/binector converter 1 (bit field 1)
n010
(2010)
Displays the status of the bits in the bit field on the bars of the 7-segment
S00
display
(B120)
Segment ON:
Segment OFF:
Connector/binector converter 2 (bit field 2)
n011
(2011)
As for n010
S00
(B120)
Connector/binector converter 3 (bit field 3)
n012
(2012)
As for n010
S00
(B120)
Binector/connector converters
Binector/connector converter 1 (bit field 4)
n013
(2013)
Displays the status of the bits in the bit field on the bars of the 7-segment
S00
display
(B121)
Segment ON:
Segment OFF:
11-100
15
14
13
12
11
10
9
6
4
7
5
3
2
1
Bit (binector) = log. "1" state
Bit (binector) = log. "0" state
15
14
13
12
11
10
9
7
6
5
4
3
2
1
Bit = log. "1" state
Bit = log. "0" state
Value range
[Unit]
Steps
[SW 1.7 and later]
0 to 999
2000 to 2005
2008 to 2999
1
0.0 to 100.0
[%]
0.1%
FB 10
8
0
FB 11
FB 12
FB 13
8
0
No. indices
Factory
setting
Type
Ind: 100
FS=0
Type: O2
Ind: 6
Type: O2
Ind: None
Type: V2
Ind: None
Type: V2
Ind: None
Type: V2
Ind: None
Type: V2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
on-line
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
6RX1700-0AD76

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents