Siemens 6RA7086-6KS22 Operating Instructions Manual page 621

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
U695
Offset compensation for analog outputs of SCI1
(2695)
Setting instructions, see Operating Instructions for SCI1
i001: Slave 1, analog output 1
i002: Slave 1, analog output 2
(Z155)
i003: Slave 1, analog output 3
(Z156)
i004: Slave 2, analog output 1
i005: Slave 2, analog output 2
i006: Slave 2, analog output 3
U696
Telegram failure time for SCB1
(2696)
Fault message F079 is displayed if no process data are exchanged with the
supplementary board within this delay period. The monitoring function is
implemented within a 20 ms cycle. For this reason, only setting values
which constitute a multiple of 20 ms are meaningful.
Settings:
0
No time monitoring
1...65000
Permissible time interval between two process data
exchange operations before a fault message is output.
Note:
The telegram monitoring function is active
from the receipt of the first error-free telegram after connection of the
electronics power supply
from the receipt of the first error-free telegram after the telegram monitor
has responded (i.e. monitoring timeout).
n697
Diagnostic information of SCB1
(2697)
Visualization parameter for displaying diagnostic info relating to SCB1.
The displayed values overflow at "255" (e.g. the number of telegrams begins
at "0" again after "255").
i001: Number of error-free telegrams
i002: Number of errored telegrams
i003: Number of voltage failures on slaves
i004: Number of interruptions in fiber-optic connection
i005: Number of missing response telegrams
i006: Number of search telegrams for slave location
i007: ETX error
i008: Number of configuration telegrams
i009: Highest terminal numbers needed according to PZD
connection (parameterization of connectors or binectors)
i010: Analog inputs/outputs required according to PZD connection of
setpoint channel and actual value output via SCI
(parameterization of appropriate connectors)
i011: Reserved
i012: Reserved
i013: SCB1 alarm word
i014: Setting defining whether slave no. 1 is needed and type if
applicable
0: No slave required
1: SCI1
2: SCI2
i015: Setting defining whether slave no. 2 is needed and type if
applicable
0: No slave required
1: SCI1
2: SCI2
i016: SCI board: Initialization error
i017: SCB1 generation: Year
i018: SCB1 generation: Day and month
i019: SCI slave1: Software version
i020: SCI slave1: Year of generation
i021: SCI slave1: Day and month of generation
i022: SCI slave2: Software version
i023: SCI slave2: Year of generation
i024: SCI slave2: Day and month of generation
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
[SW 1.9 and later]
-100.00 to 100.00
[V]
0.01V
0 to 65000
[SW 1.9 and later]
[ms]
1ms
[SW 1.9 and later]
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind:6
P052 = 3
FS= 0
P051 =40
Type I2
on-line
Ind: None
P052 = 3
FS=0
P051 =40
Type: O2
Online
Ind:24
P052 = 3
Type O2
P051 =40
on-line
11-157