05.05
PNU
Description
Enable and setting of the PI controllers
U531
Source for control signals (enable PI controller)
(2531)
0 = Binector B0000
*
1 = Binector B0001
S00
etc.
(B180...
B189)
i001:
0 = Disable controller
i002:
0 = Disable controller
...
i010:
0 = Disable controller
i011:
1 = Freeze I component
i012:
1 = Freeze I component
...
i020:
1 = Freeze I component
i021:
1 = Freeze output
i022:
1 = Freeze output
...
i030:
1 = Freeze output
i031:
1 = Freeze I component in pos.direction PI controller 1
i032:
1 = Freeze I component in pos.direction PI controller 2
...
i040:
1 = Freeze I component in pos.direction PI controller 10
i041:
1 = Freeze I component in neg.direction PI controller 1
i042:
1 = Freeze I component in neg.direction PI controller 2
...
i050:
1 = Stop I component in neg.direction
U532
Source for control signals (set PI controller)
(2532)
0 = Binector B0000
*
1 = Binector B0001
S00
etc.
(B180...
B189)
i001:
0 = Set I component
i002:
0 = Set I component
...
i010:
0 = Set I component
i011:
0 = Set output
i012:
0 = Set output
...
i020:
0 = Set output
U533
Source for Setting values
(2533)
0 = Connector K0000
*
1 = Connector K0001
S00
etc.
(B180...
B189)
i001:
Setting value for I component
i002:
Setting value for I component
...
i010:
Setting value for I component
i011:
Setting value for Output PI controller 1
i012:
Setting value for Output PI controller 2
...
i020:
Setting value for Output PI controller 10
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
[SW 1.8 and later]
PI controller 1
PI controller 2
PI controller 10
PI controller 1
PI controller 2
PI controller 10
PI controller 1
PI controller 2
PI controller 10
PI controller 10
[SW 1.8 and later]
PI controller 1
PI controller 2
PI controller 10
PI controller 1
PI controller 2
PI controller 10
[SW 1.8 and later]
PI controller 1
PI controller 2
PI controller 10
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
All binector numbers
Ind: 50
1
WE=0
Typ: L2
All binector numbers
Ind: 20
1
WE=0
Typ: L2
All connector
Ind: 20
numbers
WE=0
1
Typ: L2
Parameter list
See
Change
(Access /
Status)
P052 = 3
P051 = 40
off-line
P052 = 3
P051 = 40
off-line
P052 = 3
P051 = 40
off-line
11-147

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents