001/033 CBP_Status
Bit0: "CBP Init", CBP is being initialized or waiting to be initialized by the basic unit
Bit1: "CBP Online", CBP is selected by basic unit
Bit2: "CBP Offline", CBP not selected by basic unit
Bit3: Illegal bus address (P918)
Bit4: Diagnostic mode activated (U711 <> 0)
Bit8: Incorrect identifier bytes transferred (incorrect configuring message from PROFIBUS Master)
Bit9: Incorrect PPO type (incorrect configuring message from PROFIBUS Master)
Bit10: Correct configuring data received from PROFIBUS_DP Master (set in normal operation)
Bit12: Fatal error detected by DPS Manager software (not set in normal operation)
Bit13: Program in endless loop in main.c (loop can only be exited by a Reset)
Bit15: Program in communications online loop (loop can only be exited through re-initialization by basic unit)
002/034 SPC3_Status
Bit0:
Bit2: Diag flag
Bit3: RAM Access Violation, memory access >1.5kB
Bit4+5: DP state (00=Wait_Prm, 01=Wait_Cfg, 10=Data_Ex, 11=not possible)
Bit6+7: WD state (00=Baud search, 01=Baud_Control, 10=DP_Control, 11=not possible)
Bit8-11: Baud rate (0000=12MBd, 0001=6MBd, 0010=3MBd, 0011=1,5MBd, 0100=500kBd, 0101=187.5kBd,
Bit12-15: SPC3-Release (0000=Release 0)
003/035 SPC3_Global_Controls
Bits remain set until the next DP global command
Bit1: 1=Clear_Data message received
Bit2: 1=Unfreeze message received
Bit3: 1=Freeze message received
Bit4: 1=Unsync message received
Bit5: 1=Sync message received
004/036 L byte: No. of received error-free messages (DP Standard only)
H byte: Reserved
005/037 L byte: "Timeout" counter
H byte: Reserved
006/038 L byte: "Clear Data" counter
H byte: Reserved
007/039 L byte: "Heartbeat counter error" counter
H byte: Reserved
008/040 L byte: No. bytes for special diagnosis
H byte: Reserved
009/041 L byte: Mirroring of slot identifier 2
H byte: Mirroring of slot identifier 3
010/042 L byte: Mirroring of P918 (CB bus addr.)
H byte: Reserved
011/043 L byte: "Re-config. by CUD" counter
H byte: "Initialization runs" counter
012/044 L byte: Error ID DPS manager error
H byte: Reserved
013/045 L byte: PPO type found
H byte: Reserved
014/046 L byte: Mirroring of "DWord specifier ref"
7-26
(not set in normal operation)
(set in normal operation)
(not set in normal operation)
(not set in normal operation)
(not set in normal operation)
(not set in normal operation)
(not set in normal operation)
Offline/Passive Idle
(0=SPC3 is operating in normal mode (offline)
1=SPC3 is operating in Passive Idle)
(0=diagnostic buffer has been picked up by master
1= diagnostic buffer has not been picked up by master)
(0=no address violation, 1=for addresses > 1536 bytes, 1024 is subtracted from address and access
made to the new address)
0110=93.75kBd, 0111=45.45kBd, 1000=19.2kBd, 1001=9.6kBd)
Meaning for CBP2