Parameter list
PNU
Description
U698
Binector selection for binary outputs of SCI
(2698)
Selection of binectors whose states are output via the binary outputs of the
SCIs
i001: Binector selection for SCI slave1, binary output 1
(Z135)
i002: Binector selection for SCI slave1, binary output 2
(Z136)
i003: Binector selection for SCI slave1, binary output 3
(Z145)
i004: Binector selection for SCI slave1, binary output 4
(Z146)
i005: Binector selection for SCI slave1, binary output 5
i006: Binector selection for SCI slave1, binary output 6
i007: Binector selection for SCI slave1, binary output 7
i008: Binector selection for SCI slave1, binary output 8
i009: Binector selection for SCI slave1, binary output 9
i010: Binector selection for SCI slave1, binary output 10
i011: Binector selection for SCI slave1, binary output 11
i012: Binector selection for SCI slave1, binary output12
i013: Binector selection for SCI slave2, binary output 1
i014: Binector selection for SCI slave2, binary output 2
i015: Binector selection for SCI slave2, binary output 3
i016: Binector selection for SCI slave2, binary output 4
i017: Binector selection for SCI slave2, binary output 5
i018: Binector selection for SCI slave2, binary output 6
i019: Binector selection for SCI slave2, binary output 7
i020: Binector selection for SCI slave2, binary output 8
i021: Binector selection for SCI slave2, binary output 9
i022: Binector selection for SCI slave2, binary output 10
i023: Binector selection for SCI slave2, binary output 11
i024: Binector selection for SCI slave2, binary output12
n699
Display of SCB1/SCI process data
(2699)
All values in hexadecimal representation
i001: SCI slave1, binary inputs
(Z130)
i002: SCI slave1, analog input1
(Z131)
i003: SCI slave1, analog input2
(Z135)
i004: SCI slave1, analog input3
(Z136)
i005: SCI slave2, binary inputs
(Z140)
i006: SCI slave2, analog input1
(Z141)
i007: SCI slave2, analog input2
(Z145)
i008: SCI slave2, analog input3
(Z146)
i009: SCI slave1, binary outputs
(Z150)
i010: SCI slave1, analog output1
(Z151)
i011: SCI slave1, analog output2
(Z155)
i012: SCI slave1, analog output3
(Z156)
i013: SCI slave2, binary outputs
i014: SCI slave2, binary outputs
i015: SCI slave2, analog output2
i016: SCI slave2, analog output3
11.84 Configuration of supplementary boards in board locations 2 and 3
U710
Initialize link to supplementary boards
(2710)
i001
Initialization of 1
*
letter)
(Z110)
i002
Initialization of 2
(Z111)
letter
Settings:
0
The link to supplementary boards is re-initialized. After the
configuration parameters for supplementary boards have been
changed, U710 must be set to 0 so that the new settings can
take effect.
The parameter is then set automatically to 1.
Note: Data transmission is interrupted while initialization is in
1
Deactivated
11-158
st
communications board (in slot with lower ID
nd
communications board (in slot with higher ID
progress.
Value range
[Unit]
Steps
[SW 1.9 and later]
All binector numbers
1
[SW 1.9 and later]
0 to 1
1
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind:24
P052 = 3
FS= 0
P051 =40
Type L2
on-line
Ind:16
P052 = 3
Type L2
P051 =40
on-line
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: O2
Offline