05.05
Calculation of thermal equivalent time constant (P114)
It must be noted that the thermal equivalent time constant is dependent on the maximum overcurrent.
Thermal equivalent time constant of 1G . 5/1H . 5 DC motors according to Catalog DA12.
P114
40
30
20
10
8
6
5
4
3
2
1
I
... Rated motor armature current (=P100)
rated
I ...
Maximum overcurrent at which motor is operated
NOTES
•
When other motor types are connected, the manufacturer's specifications apply.
•
If you are using DC motors 1G.5 / 1H.5 as specified in catalog DA12, parameter P113 must
be set to 1.00
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
100
120
140
160
Function descriptions
180
200
I [%]
I
I
rated
9-33