Siemens 6RA7086-6KS22 Operating Instructions Manual page 613

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
U541
Freeze I component
(2541)
0
Controller I component frozen (i.e. pure P controller)
*
1
Controller I component active
S00
(B180...
i001:
PI controller 1
B189)
i002:
PI controller 2
...
i010:
PI controller 10
Output, Limitation
U542
Source for variable positive limit
(2542)
The content of the selected connector acts as the positive limit for the
*
output of the PI controller after multiplication with U543.
S00
0 = Connector K0000
(B180...
1 = Connector K0001
B189)
etc.
i001:
PI controller 1
i002:
PI controller 2
...
i010:
PI controller 10
Note:
If the content of the selected connector has a negative value, this causes a
negative maximum value at the output of this limiter stage.
U543
Positive limit for the output of the PI controller
(2543)
See also U542
S00
(B180...
B189)
U544
Source for variable negative Limit
(2544)
The content of the selected connector acts as the negative limit for the
*
output of the technology controller after multiplication with U510.
S00
0 = Connector K0000
(B180...
1 = Connector K0001
B189)
etc.
i001:
PI controller 1
i002:
PI controller 2
...
i010:
PI controller 10
Note:
If the content of the selected connector has a positive value, this causes a
positive minimum value at the output of this limiter stage.
Note:
Connectors K9306 to K9396 contain for PI controllers 1 to 10 the positive
limitation values formed by U542 and U543 with an inverted sign. In this
way it is possible to set the negative limitation symmetrically to the positive
limitation by setting U544= 9306 to 9396 and U545=100.0.
U545
Negative limit for the output of the PI controller
(2545)
See also U544
S00
(B180...
B189)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
[SW 1.8 and later]
0 to 1
1
[SW 1.8 and later]
All connector
numbers
1
[SW 1.8 and later]
0.0 to 199.9
[%]
0.1
[SW 1.8 and later]
All connector
numbers
1
[SW 1.8 and later]
0.0 to 199.9
[%]
0.1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 10
P052 = 3
FS=1
P051 = 40
Type: O2
off-line
Ind: 10
P052 = 3
FS=1
P051 = 40
Type: L2
off-line
Ind: 10
P052 = 3
FS=100.0
P051 = 40
Type: O2
on-line
Ind: 10
P052 = 3
FS=
P051 = 40
i001: 9306
off-line
i002: 9316
i003: 9326
i004: 9336
i005: 9346
i006: 9356
i007: 9366
i008: 9376
i009: 9386
i010: 9396
Type: L2
Ind: 10
P052 = 3
FS=100.0
P051 = 40
Type: O2
on-line
11-149