Siemens 6RA7086-6KS22 Operating Instructions Manual page 535

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
Display of status words 1 and 2
r652
Display of status word 1
Mode of representation on operator panel (PMU):
(G182)
Segments 0 to 15 correspond to bits 0 to 15 of the status word
Segment ON:
Segment OFF:
r653
Display of status word 2
Mode of representation on operator panel (PMU):
(G183)
Segments 0 to 15 correspond to bits 16 to 31 of the status word
Segment ON:
Segment OFF:
The following parameters are used to select the binectors (some of which are gated with one another or with other signals) to be applied to
the individual bits of the control word.
The settings of all these parameters are as follows:
0 = binector B0000
1 = binector B0001
etc.
The functions and logic operations are also shown on Sheets G180 and G181 in Section 8.
Control word 1
P654
Source for control word 1, bit0
*
(0=OFF1, 1=ON; ANDed with terminal 37)
BDS
(G130)
P655
1st source for control word 1, bit1
*
(0=OFF2; ANDed with 2
BDS
(G180)
P656
2nd source for control word 1, bit1
*
(0=OFF2; ANDed with 1
BDS
(G180)
P657
3rd source for control word 1, bit1
*
(0=OFF2; ANDed with 1
BDS
(G180)
P658
1st source for control word 1, bit2
*
(0=OFF3=Fast stop; ANDed with 2
BDS
(G180)
P659
2nd source for control word 1, bit2
*
(0=OFF3=Fast stop; ANDed with 1
BDS
(G180)
P660
3rd source for control word 1, bit2
*
(0=OFF3=Fast stop; ANDed with 1
BDS
(G180)
P661
Source for control word 1, bit3
*
(0=pulse disable, 1=enable; ANDed with terminal 38)
BDS
(G180)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
15
14
13
12
11
10
9
7
6
5
4
3
2
1
Corresponding bit is in log. "1" state
Corresponding bit is in log. "0" state
15
14
13
12
11
10
9
7
6
5
4
3
2
1
Corresponding bit is in log. "1" state
Corresponding bit is in log. "0" state
nd
rd
and 3
sources for bit1)
st
rd
and 3
sources for bit1)
st
nd
and 2
sources for bit1)
nd
rd
and 3
sources for bit2)
st
rd
and 3
sources for bit2)
st
nd
and 2
sources for bit2)
Value range
[Unit]
Steps
8
0
8
0
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: None
P052 = 3
Type: V2
Ind: None
P052 = 3
Type: V2
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
11-71

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents