Siemens 6RA7086-6KS22 Operating Instructions Manual page 537

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
PNU
Description
P684
Source for control word 2, bit24
*
(0=n controller speed droop disabled, 1=enabled)
BDS
(G181)
P685
Source for control word 2, bit25
*
(0=n controller disabled, 1=n controller enabled)
BDS
(G181)
P686
Source for control word 2, bit26
*
(0=external fault 2, 1=no external fault 2)
BDS
(G181)
P687
Source for control word 2, bit27
*
(0=master drive, speed control, 1=slave drive, torque control)
BDS
(G181)
P688
Source for control word 2, bit28
*
(0=external alarm 1, 1=no external alarm 1)
BDS
(G181)
P689
Source for control word 2, bit29
*
(0=external alarm 2, 1=no external alarm 2)
BDS
(G181)
P690
Source for control word 2, bit30
*
(0=select Bico data set 1, 1=select Bico data set 2)
(G181)
P691
Source for control word 2, Bit31
*
Main contactor checkback signal:
BDS
(0 = main contactor dropped out, 1 = main contactor picked up)
(G181)
This control input is intended as a means of looping an auxiliary contact of
the main contactor into the device control.
During the Power ON routine, this signal must switch to "1" within the time
period set in P095. If it does not, or it disappears during operation, fault
message F004 with fault value 6 is activated.
P691 = 0: Bit 31 of control word 2 is inoperative.
(This setting of P691 is always active, regardless of whether
control word 2 is input in word mode [P649 = 9] or bit mode
[P649 <> 9])
P691 = 1: Bit 31 of control word 2 is inoperative.
(This setting of P691 is active only when control word 2 is input
in bit mode, i.e. when P649 <> 9)
11.37 Further configuring measures
P692
Source for selection of injection of standstill field
*
Selection of binector to control injection of the standstill field ("0" state =
BDS
inject standstill field)
(G166)
Note:
The delay time set in P258 is not effective when this function is
active.
0 = binector B0000
1 = binector B0001
etc.
P693
Source for selection of enabling command for EMF controller
*
Selection of binector which is to control enabling of the EMF controller
BDS
0 = binector B0000
(G165)
1 = binector B0001
etc.
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Value range
[Unit]
Steps
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
All binector numbers
1
[SW 1.8 and later]
All binector numbers
1
All binector numbers
1
All binector numbers
1
Parameter list
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
Ind: None
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=0
P051 = 40
Type: L2
Offline
Ind: 2
P052 = 3
FS=1
P051 = 40
Type: L2
Offline
11-73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents