Siemens 6RA7086-6KS22 Operating Instructions Manual page 163

6ra70 series, microprocessor-based converters from 6kw to 2500kw for variable-speed dc drives, simoreg dc master
Table of Contents

Advertisement

05.05
Control bits from OP1S operator panel:
(see also function diagram "OP1S operational display" (Section 8, Sheet Z123) and the OP1S
operating instructions)
Data are exchanged between the OP1S and SIMOREG 6RA70 converter via the G-SST1 interface
(RS485) and USS protocol.
The OP1S operator panel transfers the following control bits in process data word 1 in the USS
message:
Key on OP1S
ON key / OFF key (I / 0)
Reset
Jog
Reverse
UP key
DOWN key
*)
Suggested functions. Since binectors can be freely wired up to any selector switch, the control signals from the OP1S
can be used for any type of control task in the SIMOREG 6RA70.
Connection of control signals from the OP1S for the suggested functions:
Functions can be implemented via the OP1S only if the following conditions are fulfilled:
1) Bit-by-bit input of control bits in control word 1 (P648 = 9), see also Section 8, Function
Diagrams, Sheet G180
2) OP1S in "Operational display" status
ON / OFF1:
Parameterization of switch-on/shutdown via OP1S by setting
P654 = 2100
Please also note AND operation with "Switch-on/Shutdown" from terminal 37 (see also Function
Diagrams, Sheet G130 in Section 8 and Section "Switch-on/Shutdown (ON / OFF) terminal 37" in
Section 9)
Acknowledge:
Parameterization of fault message acknowledgements via OP1S by setting
P665, P666 or P667 = 2107
Faults can always be acknowledged by pressing the <P> key on the PMU.
Inching:
Parameterization of inching via OP1S by setting
P668 or P669 = 2108
Selection of source of inching setpoint via the corresponding index of P436 (see "Inching setpoint"
function diagram)
Direction of rotation enable:
Parameterization of direction of rotation enabling via OP1S by setting
P671 = 2111 (positive direction of rotation)
P672 = 2112 (negative direction of rotation)
Motorized potentiometer:
Parameterization of motorized potentiometer via OP1S by setting
P673 = 2113 (higher)
P674 = 2114 (lower)
P644 = 240 (main setpoint from motorized potentiometer)
SIEMENS AG
6RX1700-0AD76
SIMOREG DC Master
Operating Instructions
Function *)
ON / OFF1
Acknowledge
Jog (inch)
Enable positive direction of rotation
Enable negative direction of rotation
Increase motorized potentiometer
Decrease motorized potentiometer
Bit in PZD word1
(connector K2001)
Bit 0
Bit 7
Bit 8
Bit 11
Bit 12
Bit 13
Bit 14
Start-Up
Binector
B2100
B2107
B2108
B2111
B2112
B2113
B2114
7-5