Parameter list
PNU
Description
11.51 Resetting and storing parameters,
list of existing and modified P and r parameters
P970
Restore factory setting
*
Reset parameters to factory setting (default)
0:
Parameter reset: All parameters are reset to their original values
(factory setting). This parameter is then automatically reset to 1.
1:
No parameter reset
Note: Function can also be selected by setting P051=21.
P971
EEPROM transfer
*
Transfer of parameter values from RAM to EERPROM on switchover from 0
to 1.
It takes approximately 15s to process all values. The PMU remains in value
mode for this period.
r980
List of existing parameter numbers, start
Visualization parameter for displaying the first 100 parameter numbers in
the P or r parameter range (0 to 999). The parameter numbers are listed in
ascending sequence.
Repetition of a number over several indices means that there are no further
parameter numbers in the 0 to 999 range.
The list is continued at the parameter whose number is displayed under
index 101.
See also r989
r981
List of existing parameter numbers, continuation
See r980.
r982
List of existing parameter numbers, continuation
See r980.
r983
List of existing parameter numbers, continuation
See r980.
r984
List of existing parameter numbers, continuation
See r980.
r985
List of existing parameter numbers, continuation
See r980.
r986
List of existing parameter numbers, continuation
See r980.
r987
List of existing parameter numbers, continuation
See r980.
r988
List of existing parameter numbers, continuation
See r980.
r989
List of existing parameter numbers, continuation
Continuation of the list can be found under index 101. Please note:
860
=
r860 (TECH BOARD installed)
2980
=
n980
See also r980.
r990
List of modified parameter numbers, start
Visualization parameter for displaying the first 100 modified parameters in
the P or r parameter range (0 to 999). The parameter numbers are listed in
ascending sequence.
Repetition of a number over several indices means that there are no further
modified parameters in the 0 to 999 range.
The list is continued at the parameter whose number is displayed under
index 101.
See also r999.
r991
List of modified parameter numbers, continuation
See r990.
11-98
Value range
No. indices
[Unit]
Factory
Steps
setting
Type
0 to 1
Ind: None
1
FS=1
Type: O2
0 to 1
Ind: None
1
FS=0
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
Ind: 101
Type: O2
SIEMENS AG
SIMOREG DC Master
Operating Instructions
05.05
See
Change
(Access /
Status)
P052 = 3
P051 = 40
Offline
P052 = 3
P051 = 40
Offline
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3
P052 = 3