Parameter list
PNU
Description
n < n comp. signal
P373
Speed threshold n comp.
Speed threshold for n < n comp. signal
FDS
(G187)
P374
Hysteresis for < n comp. signal (n < n comp. signal)
This value is added to the response threshold if n < n comp. is active.
FDS
(G187)
P375
OFF delay for n < n comp. signal
FDS
(G187)
Setpoint/actual value deviation 2
P376
Permissible setpoint/actual value deviation 2
FDS
(G187)
P377
Hysteresis for setpoint/actual value deviation 2 signal
FDS
This value is added to the response threshold if a setpoint/actual value
(G187)
deviation signal is active
P378
Response delay for setpoint/actual value deviation signal 2
FDS
(G187)
Overspeed
P380
Maximum speed in positive direction of rotation
FDS
(G188)
P381
Maximum speed in negative direction of rotation
FDS
(G188)
Setpoint/actual value deviation 1
P388
Permissible deviation between setpoint and actual value 1
FDS
(G187)
P389
Hysteresis for setpoint/actual value deviation signal 1
This value is added to the response threshold if a setpoint/actual value
FDS
deviation signal is active
(G187)
P390
Response delay for setpoint/actual value deviation signal 1
FDS
(G187)
I f < I f min signal
P394
Field current threshold I f min
Field current threshold for I f < I f min limit-value monitor .
FDS
Note:
(G188)
This threshold affects the sequence of control operations for the "Direction
of rotation reversal using field reversal" and "Braking with field reversal"
functions (see Section 9).
The I f < I f min signal is connected to binector B0215, the actual value at
field current controller input K0265 is applied as I f .
B0215 = 0 when K0265 > threshold set in P394
B0215 = 1 when K0265 < threshold set in P394 + hysteresis set in P395
0 → 1 transition takes place when K0265 < P394
1 → 0 transition takes place when K0265 > P394 + P395
11-46
Value range
[Unit]
Steps
0.00 to 199.99
[%]
0.01% of maximum
speed
0.00 to 199.99
[%]
0.01% of maximum
speed
0.0 to 100.0
[s]
0.1s
[SW 1.9 and later] 0.00 to 199.99
[%]
0.01% of maximum
speed
0.00 to 199.99
[%]
[SW 1.9 and later]
0.01% of maximum
speed
0.0 to 100.0
[SW 1.9 and later]
[s]
0.1s
0.0 to 199.9
[%]
0.1% of maximum
speed
-199.9 to 0.0
[%]
0.1% of maximum
speed
0.00 to 199.99
[%]
0.01% of maximum
speed
0.00 to 199.99
[%]
0.01% of maximum
speed
0.0 to 100.0
[s]
0.1s
0.00 to 199.99
[%]
0.01% of converter
rated field DC
current (r073.i02)
SIMOREG DC Master
05.05
No. indices
See
Factory
Change
setting
(Access /
Type
Status)
Ind: 4
P052 = 3
FS=100.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=3.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=3.0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FD=3.00
P051 = 40
Type: O2
on-line
Ind: 4
P052 = 3
FS=1.00
P051 = 40
Type: O2
on-line
Ind: 4
P052 = 3
FS=3.0
P051 = 40
Type: O2
on-line
Ind: 4
P052 = 3
FS=120.0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=-120.0
P051 = 40
Type: I2
Online
Ind: 4
P052 = 3
FS=3.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=1.00
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=3.0
P051 = 40
Type: O2
Online
Ind: 4
P052 = 3
FS=3.00
P051 = 40
Type: O2
Online
SIEMENS AG
6RX1700-0AD76
Operating Instructions