Setup Procedure
(16) Read the A/D value
AN0BUF0B (0x0000A430)
AN1BUF0B (0x0000A470)
(17) Read the A/D value
AN2BUF10 (0x0000A4A0)
Do not start the same AD conversion using the external trigger B during AD conversion. Con-
version result is not stored properly. AD conversion start timing should be well considered in
using the external trigger B.
..
..
(16) Read the A/D0 conversion data buffer 0B and A/D1
conversion data buffer 0B (AN0BUF0B, AN1BUF0B)
by the AD0 complete B interrupt processing after the A/
D0 conversion is completed.
(17) Read the A/D2 conversion data buffer 10 (AN2BUF10)
by the AD2 complete B interrupt processing after the A/
D2 conversion is completed..
Description
Operation
Chapter 14
A/D Converter
XIV - 43