Panasonic MN103S User Manual page 318

Panaxseries
Hide thumbs Also See for MN103S:
Table of Contents

Advertisement

Chapter 10
Motor Control PWM
PWM1 Output Control Register (PWMSEL1: 0x0000A338) [8,16-bit Access Register]
bp
15
14
Flag
-
-
At reset
0
0
Access
R
R
bp
Flag
15-12
-
11
PSELN12
10
PSEL12
9
PSELN11
8
PSEL11
7
PSELN10
6
PSEL10
5
OTLVN12
4
OTLV12
3
OTLVN11
2
OTLV11
1
OTLVN10
0
OTLV10
X - 10
Control Registers
13
12
11
10
PSEL
PSEL
-
-
N12
12
0
0
0
0
R
R
R/W
R/W
Description
-
NPWM12 output sources
PWM12 output sources
NPWM11 output sources
PWM11 output sources
NPWM10 output sources
PWM10 output sources
NPWM12 H/L level output
PWM12 H/L level output
NPWM11 H/L level output
PWM11 H/L level output
NPWM10 H/L level output
PWM10 H/L level output
9
8
7
6
PSEL
PSEL
PSEL
PSEL
N11
11
N10
10
0
0
0
0
R/W
R/W
R/W
R/W
Setting condition
-
0: PWM output
1: H/L level output
0: PWM output
1: H/L level output
0: PWM output
1: H/L level output
0: PWM output
1: H/L level output
0: PWM output
1: H/L level output
0: PWM output
1: H/L level output
0: L level output
1: H level output
0: L level output
1: H level output
0: L level output
1: H level output
0: L level output
1: H level output
0: L level output
1: H level output
0: L level output
1: H level output
5
4
3
2
OTLV
OTLV
OTLV
OTLV
N12
12
N11
11
0
0
0
0
R/W
R/W
R/W
R/W
1
0
OTLV
OTLV
N10
10
0
0
R/W
R/W