Serial 1 Status Register (SC1STR: 0x0000A119) [8,16-bit Access Register]
bp
7
6
Flag
SCA1
SCA1
TBSY
RBSY
At reset
0
0
Access
R
R
bp
Flag
Description
Transmission status flag
7
SCA1TBSY
Reception status flag
6
SCA1RBSY
5
-
-
Reception data flag
4
SCA1RXA
3
-
-
Framing error
2
SCA1FE
Parity error
1
SCA1PE
Overrun error
0
SCA1OE
Do not to write data to any of the serial interface status registers.
..
..
5
4
3
2
SCA1
SCA1
-
-
RXA
FE
0
0
0
0
R
R
R
R
1
0
SCA1
SCA1
PE
OE
0
0
R
R
Setting condition
0: Can transmit
1: On transmitting
0: Can receive
1: On receiving
-
0: No available
1: Available
-
0: No error detected
1: Error detected
0: No error detected
1: Error detected
0: No error detected
1: Error detected