Optical Systems Design OSD2700SFP SERIES Operator's Manual page 188

Managed 24-port 100base sfp and 4- combo port gigabit ethernet switch
Table of Contents

Advertisement

2.
Usage:
Use snmp-server trap-type enable linkUp command to enable link up trap for SNMP.
Use the no snmp-server trap-type enable linkUp command to disable link up trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable linkUp
4.
Example:
The following example enables link up trap for SNMP:
switch_a(config)#snmp-server trap-type enable linkUp
switch_a(config)#
MAC Notification Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to enable the Switch to send MAC Notification Trap to the network management
system (NMS).
Use the no parameter with this command to disable the Switch to send MAC Notification Trap to the
network management system (NMS).
3.
Command Syntax:
snmp-server trap-type enable mac-notification
no snmp-server trap-type enable mac-notification
4.
Example:
The following example enables the Switch to send MAC Notification Trap to the network management
system (NMS):
switch_a(config)#snmp-server trap-type enable mac-notification
switch_a(config)#
MAC Notification Interval:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to specify the MAC notification trap interval in seconds between each set of traps
that are generated.
3.
Command Syntax:
snmp-server mac-notification interval <1-65535>
<1-65535> The MAC notification trap interval in seconds.
4.
Example:
The following example sets MAC notification trap interval time 10 seconds:
switch_a(config)# snmp-server mac-notification interval 10
switch_a(config)#