Optical Systems Design OSD2700SFP SERIES Operator's Manual page 138

Managed 24-port 100base sfp and 4- combo port gigabit ethernet switch
Table of Contents

Advertisement

RATE CONTROL
1.
Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2.
Usage:
Use this command to specify the ingress/egress rate to be used for each interface. The bandwidth value
is in bits.
Use the no parameter with this command to remove the ingress/egress rate to be used for each
interface.
3.
Command Syntax:
(no) rate-control ingress/egress VALUE
VALUE
<1-10000000000 bits> (usable units: k, m, g)
<1-999>k|m for 1 to 999 kilo bits or mega bits.
1g for 1 giga bits.
4.
Example:
The following example shows the use of rate-control ingress VALUE (10 mega bits) to the interface
fe1 (port 1):
switch_a(config)#interface fe1
switch_a(config-if)#rate-control ingress 10m
switch_a(config-if)#
RMON STATISTICS
1.
Command Mode: Exec mode or Privileged Exec mode
Logon to Exec Mode (View Mode) or Privileged Exec Mode (Enable Mode).
The switch_a> or switch_a# prompt will show on the screen.
switch_a>
switch_a#
2.
Usage:
Use the show interface statistics command to display RMON statistics of interface.
3.
Command Syntax:
show interface statistics IFNAME
IFNAME specifies the name of the interface for which RMON statistics is desired.
4.
Example:
The following example shows the use of show interface statistics to display RMON statistics of the
interface fe1 (port 1):
switch_a>show interface statistics fe1
PAGE 138
OSD2700SFP OPERATOR MANUAL
OPTICAL SYSTEMS DESIGN
DOC ID: 10112704