Optical Systems Design OSD2700SFP SERIES Operator's Manual page 143

Managed 24-port 100base sfp and 4- combo port gigabit ethernet switch
Table of Contents

Advertisement

Use this command to enable or disable a loopback detection on a port interface.
3.
Command Syntax:
bridge GROUP loopback-detect (enable | d isable)
GROUP <1-1> Bridge-group ID used for bridging.
enable Enables a loopback detection on a port interface.
disable Disables a loopback detection on a port interface.
4.
Example:
The following example enables a loopback detection for bridge GROUP (1):
switch_a(config)#bridge 1 loopback-detect enable
switch_a(config)#
LoopBack Detect Action:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to configure action while loopback detected.
3.
Command Syntax:
bridge GROUP loopback-detect action (errdisable | n one (default))
GROUP <1-1> Bridge-group ID used for bridging.
errdisable Enable error disable LoopBack Detect Action on a port interface.
none Disable error disable LoopBack Detect Action on a port interface.
4.
Example:
The following example enables error disable LoopBack Detect Action for bridge GROUP (1):
switch_a(config)#bridge 1 loopback-detect action errdisable
switch_a(config)#
Error Disable Recovery:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to set the error disable recovery time interval. The range of interval value is from 0
to 65535. And the default value is 0 second (no recovery).
3.
Command Syntax:
bridge GROUP loopback-detect errdisable-recovery <0-65535>
GROUP <1-1> Bridge-group ID used for bridging.
<0-65535> The error disable recovery time in seconds.
PAGE 143
OSD2700SFP OPERATOR MANUAL
OPTICAL SYSTEMS DESIGN
DOC ID: 10112704

Advertisement

Table of Contents
loading