Optical Systems Design OSD2184P Operator's Manual

Micro 10/100/1000base-t to 100basefx/1000base-x 3-port switch with ieee802.3af/at/bt and poh poe source

Advertisement

Quick Links

OPERATOR MANUAL
OSD2184P
MICRO 10/100/1000Base-T to 100Base-
Fx/1000Base-X
3-PORT SWITCH
With IEEE802.3af/at/bt and PoH PoE Source

Advertisement

Table of Contents
loading

Summary of Contents for Optical Systems Design OSD2184P

  • Page 1: Index

    OPERATOR MANUAL OSD2184P MICRO 10/100/1000Base-T to 100Base- Fx/1000Base-X 3-PORT SWITCH With IEEE802.3af/at/bt and PoH PoE Source...
  • Page 4: Table Of Contents

    INSTALLATION AND OPERATION ................... 12 INTRODUCTION ........................12 INSTALLATION ........................12 2.2.1 WARNING AND PRECAUTIONS ................... 12 2.2.2 OSD2184P DRAWINGS AND DIMENSIONS ..............13 2.2.3 POWER SUPPLY CONNECTIONS ................. 14 2.2.4 LOCATION ........................15 2.2.5 FIXED RJ45 COPPER PORT PIN ASSIGNMENTS ............15 2.2.6...
  • Page 5 OPTICAL SYSTEMS DESIGN FIGURE 1: OSD2184P TYPICAL CONFIGURATIONS ............... 7 FIGURE 2: FRONT AND REAR PANELS ..................11 FIGURE 3: DIMENSIONS ........................13 FIGURE 4: DIN RAIL MOUNTING ..................... 13 FIGURE 5: POWER SUPPLY CONNECTIONS .................. 14 FIGURE 6: FIXED RJ45 ETHERNET CONNECTORS ............... 15 FIGURE 7: LED INDICATORS ......................
  • Page 6: Technical Summary

    VOIP phones to be easily connected to your network. With a compact design the OSD2184P can easily be mounted inside a network enclosure or a Smart Pole using the DIN rail or wall mounting brackets provided. Additionally, the OSD2184PW version can be powered from a 12VDC to 57VDC supply.
  • Page 7: Typical Configuration

    Figure 1 below indicates the typical set-up for an OSD2184P system. FIGURE 1: OSD2184P TYPICAL CONFIGURATIONS PRODUCTS AND OPTIONS There are two options available for the OSD2184P as identified in Table 1 below. This must be specified at time of sale. TABLE 1: PRODUCTS AND OPTIONS...
  • Page 8: Technical Specifications

    (pins 1/2 positive/ 3/6 negative & 4/5 positive, 7/8 negative) Input Voltage: +46V to +57V @ 8W + PoE output power for PD devices OSD2184P PoE Power Output PoE Voltage: Vin – Vdrop Input Voltage: +12V to +57V @ 15W + PoE output power for PD devices...
  • Page 9 OPTICAL SYSTEMS DESIGN PoE Output Power Budget (Total Power of Two Copper Ports) DOC ID: 10119601 PAGE 9 OSD2184P OPERATOR MANUAL...
  • Page 10 Mode 4P CDP Enable BT Special Enable BT Class0=Class4 Enable 60W, 90W 2P 3Finger Enable 4P 4Finger Enable BT with PoH Enable BT PoH Like on all Enable Class BT Special Class 4 Enable DOC ID: 10119601 PAGE 10 OSD2184P OPERATOR MANUAL...
  • Page 11: Front And Rear Panels

    Fixed RJ45 Copper Port 1 Power Input SFP Port 2 Front Panel Fixed RJ45 Copper Port 3 3-way DIP-Switch USB port PoE Mode Push Button Erase/Restore Push Button Rear Panel FIGURE 2: FRONT AND REAR PANELS DOC ID: 10119601 PAGE 11 OSD2184P OPERATOR MANUAL...
  • Page 12: Installation And Operation

    2 INSTALLATION AND OPERATION INTRODUCTION This section outlines the methods required to install and operate the OSD2184P successfully. It should be studied carefully if damage to the equipment or poor results are to be avoided. This equipment has been fully tested prior to dispatch and is ready for immediate operation. However it is advisable to check for external transportation damage before operation.
  • Page 13: Osd2184P Drawings And Dimensions

    OSD2184P DRAWINGS AND DIMENSIONS The standard OSD2184P is designed to be mounted on an even surface and to be secured by means of M4 or smaller screws. All dimensions are in mm. The unit also can be mounted on a standard DIN rail with the OSD2184P DIN Rail bracket (supplied with 4 screws).
  • Page 14: Power Supply Connections

    2.2.3 POWER SUPPLY CONNECTIONS IMPORTANT! There are two options available for the OSD2184P: The OSD2184P and OSD2184PW. The Table below (Table 4) indicates the power requirements for each. They both require external DC power which is connected via the 2-way terminal block located on the front panel as shown in Figure 5.
  • Page 15: Location

    OPTICAL SYSTEMS DESIGN 2.2.4 LOCATION As with any electrical device, the OSD2184P should be placed where the unit will not be subjected to extreme temperatures, humidity, or electromagnetic interference. Specifically, the site selected should meet the following requirements: • The ambient temperature should be between -40°C to 75°C (-72°F to 167°F).
  • Page 16: Led Indicators

    PoE Mode See Table 7 Green See Table 7 Notes: When PoE LED is on it indicates that the unit is supplying power to the PSE Activity indicates traffic for copper port DOC ID: 10119601 PAGE 16 OSD2184P OPERATOR MANUAL...
  • Page 17: Controls

    OPTICAL SYSTEMS DESIGN 2.2.7 CONTROLS The OSD2184P/PW has a number of control functions: a 3-Way DIP Switch, Erase/Restore push button and a PoE Mode push button. Function PoE Mode Optical Port Speed Control ON Position Erase Restore OFF Position FIGURE 8: CONTROLS 3-Way DIP Switch THE 3-WAY DIP SWITCH IS USED TO CONTROL A NUMBER OF FUNCTIONS.
  • Page 18: Fitting Sfp Connectors

    Removing SFP – Remove fiber connector. Pull the SFP lever down to unlock SFP from housing. Using the lever, gently pull the SFP out. Fiber SFP Inserting Removing FIGURE 9: FITTING/REMOVING SFP CONNECTORS DOC ID: 10119601 PAGE 18 OSD2184P OPERATOR MANUAL...
  • Page 19: Basic Connections

    OPTICAL SYSTEMS DESIGN 2.2.9 BASIC CONNECTIONS Figure 10 shows basic user connections to the OSD2184P/PW. Chassis Ground LC Fiber cable Ethernet cable Ethernet cable Power FIGURE 10: BASIC CONNECTIONS DOC ID: 10119601 PAGE 19 OSD2184P OPERATOR MANUAL...
  • Page 20: Single/Dual Signature Pd Operation

    OPTICAL SYSTEMS DESIGN SINGLE/DUAL SIGNATURE PD OPERATION The OSD2184P supports single, dual or either single/dual signature PD by automatically detecting the user PD signature. 2.3.1 SINGLE SIGNATURE PD A “single signature PD” shares the same detection signature, classification signature, and maintains power signature between both pair sets.
  • Page 21: Command Line Interface (Cli)

    The Command Line Interface (CLI) is a useful tool for checking link status and debugging link connections. To enable the use of CLI, the OSD2184P must be connected to a PC with a USB port via a Mini USB to (typically) USB Type A cable. Using a terminal emulation program such as hyperterminal or SSCOM, a number of command lines specific to the OSD2184P can be implemented.
  • Page 22: Command Line Functions

    Displays current IP, Mask and Gateway. ipconfig IP Configuration Figure 17 Provides ability to change the IP settings. Allows the user to reset the unit to factory Default Setting Figure 18 default. DOC ID: 10119601 PAGE 22 OSD2184P OPERATOR MANUAL...
  • Page 23 PoE Dump - <poe_dump> FIGURE 16: CLI – POE DUMP Displays the current PoE output status of the following; Port PS Type Current Voltage Power Requested Power Assigned Class on AlternativeA Class on AlternativeB Status DOC ID: 10119601 PAGE 23 OSD2184P OPERATOR MANUAL...
  • Page 24 – Exits the default configuration setting and returns to the home prompt. y – Resets to default configuration sequence. The unit will require a reboot (see Page 33) for changes to take effect. DOC ID: 10119601 PAGE 24 OSD2184P OPERATOR MANUAL...
  • Page 25: Web Gui

    OPTICAL SYSTEMS DESIGN WEB GUI The OSD2184P/PW provides a web-based browser interface for configuring and monitoring the unit. This interface allows you to access the switch using any preferred web browser. This chapter describes how to configure the switch using its web-based browser interface.
  • Page 26: Logging On To The Switch

    A table displaying system information is also displayed containing MAC address, Serial Number, Software, IP address, etc. 2.5.2 GUI MENU The user has access to Configure, Monitor or Maintain the OSD2184P/PW. Each section will be explained within this manual. DOC ID: 10119601 PAGE 26...
  • Page 27 Current: Displays the current saved Subnet Mask EFAULT ATEWAY Configured: The Default Gateway can be changed by modifying this window. Current: Displays the current saved Default Gateway Buttons : saves the new settings : resets any changes made DOC ID: 10119601 PAGE 27 OSD2184P OPERATOR MANUAL...
  • Page 28 EGACY EVICE The OSD2184P provides legacy PoE support. A blue button indicates the Enable/Disable setting. The OSD2184P provides the user to select 2 pair or 4 pair. A blue button indicates the setting. AXIMUM OWER The user can set the output maximum power to each port. A blue button indicates the setting.
  • Page 29 OPTICAL SYSTEMS DESIGN NRUSH URRENT Some PDs require very high inrush current (up to 1.6A). The OSD2184P/PW can support PDs with high inrush current. A tick indicates that high inrush current mode is enabled Buttons : saves the new settings...
  • Page 30 Up: Connection established Down: No Connection detected PEED Indicates the port connection speed in Mbps. • 10: 10Mbps • 100: 100Mbps • 1000: 1000Mbps (1Gbps) UPLEX Indicates port connection type. Full, Half DOC ID: 10119601 PAGE 30 OSD2184P OPERATOR MANUAL...
  • Page 31 Indicates the class type on Alternative A from the relevant PoE port/channel LASS ON LTERNATIVE Indicates the class type on Alternative B from the relevant PoE port/channel TATUS Indicates the detected PD class on the relevant port/channel DOC ID: 10119601 PAGE 31 OSD2184P OPERATOR MANUAL...
  • Page 32 This process takes several seconds. The webpage will redirect to the “System Information” page. Please check this page to ensure that the Software ID Number has been uploaded by the new software. Buttons : Browse file location : Upload software DOC ID: 10119601 PAGE 32 OSD2184P OPERATOR MANUAL...
  • Page 33 Click the Upload button. The firmware will be uploaded to the unit. Please wait until firmware has been uploaded completely as shown below and wait until the system has rebooted. AINTANANCE YSTEM EBOOT Use this section to reboot the unit Buttons : Reboots the unit DOC ID: 10119601 PAGE 33 OSD2184P OPERATOR MANUAL...
  • Page 34: Maintenance

    OPTICAL SYSTEMS DESIGN 3 MAINTENANCE INTRODUCTION The following section outlines the fault-finding procedure for the OSD2184P/PW modems. Please take note of the following: ▲ Personnel without appropriate training should not attempt any maintenance except that outlined below. ▲ If further maintenance is attempted you are warned that every care should be taken to ensure that...
  • Page 35: Warranty

    For warranty period, please call your local OSD distributor. REPAIRS Optical Systems Design reserves the right to repair or replace faulty modules/units. Please obtain a “Return Material Authorisation” (RMA) form and number before returning goods. Goods must be returned in adequate packing material to Optical Systems Design, Warriewood or its nominated authorised representative, for all repairs.
  • Page 36 OPTIC L Optical Systems Design Pty. Ltd. 7/1 Vuko Pl. Warriewood 2102 SYSTEMS P.O. Box 891 Mona Vale N.S.W. Australia 2103 Telephone: +61 2 9913 8540 DESIGN Facsimile: +61 2 9913 8735 Email: sales@osd.com.au PTY LTD A.B.N. 83 003 020 504 Web Site: www.osd.com.au...

Table of Contents