Tx-pow Alarm (Warning) Threshold:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to set transmitted output power alarm (warning) threshold for SFP transceiver.
3.
Command Syntax:
sfp set-tx-pow IFNAME high-alarm
IFNAME specifies the name of the interface for which status and configuration information is desired.
LEVEL Threshold value -30 ~ 8.16 dbm.
4.
Example:
The following example sets high transmitted output power alarm threshold 8.16 dbm for SFP
transceiver of interface ge1 (port G1):
switch_a(config)#sfp set-tx-pow ge1 high-alarm 8.16
switch_a(config)#
Rx-pow Alarm (Warning) Threshold:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to set received optical power alarm (warning) threshold for SFP transceiver.
3.
Command Syntax:
sfp set-rx-pow IFNAME high-alarm
IFNAME specifies the name of the interface for which status and configuration information is desired.
LEVEL Threshold value -30 ~ 8.16 dbm.
4.
Example:
The following example sets high received optical power alarm threshold 8.16 dbm for SFP transceiver
of interface ge1 (port G1):
switch_a(config)#sfp set-rx-pow ge1 high-alarm 8.16
switch_a(config)#
PAGE 137
OSD2700SFP OPERATOR MANUAL
OPTICAL SYSTEMS DESIGN
h igh-warning
h igh-warning
l ow alarm
l ow warning LEVEL
l ow alarm
l ow warning LEVEL
DOC ID: 10112704