7.11 SNMP

SNMP General Setting, SNMP v1/v2c, SNMP v3
SNMP GENERAL SETTING
SNMP Status:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use snmp-server enable command to enable and no snmp-server enable command to disable SNMP
to the switch.
3.
Command Syntax:
(no) snmp-server enable
4.
Example:
The following example enables SNMP to the switch:
switch_a(config)#snmp-server enable
switch_a(config)#
Description:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use snmp-server description command to specify and no snmp-server description command to
remove description for SNMP.
3.
Command Syntax:
snmp-server description DESCRIPTION
no snmp-server description
DESCRIPTION The description for SNMP.
4.
Example:
The following example specifies description (description) for SNMP:
switch_a(config)#snmp-server description description
switch_a(config)#
Location:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
PAGE 185