SAMSUNG
COMBINED SYSTEMS PROGRAMMING MANUAL
MMC: 812
FOR:
DCS
CII
816
Purpose: Selects country for correct programming and operation.
This MMC should be run before any other programming is done to ensure
that the correct software for your country has been selected, or to change
the selection if required.
When using this MMC, the system is restarted and memory cleared to make the selec-
tion effective.
Note: You do not need to enable system programming in MMC 800 in order to run this program
but you will still require the technician's passcode.
ACTION
1. Open programming and select 812
Display shows the country selected by the installer
(e.g. UK).
To accept this setting, go to step 4.
2. Press VOLUME keys to select a different country
and press RIGHT soft key
3. Press VOLUME keys to select YES or NO and
press RIGHT soft key
Warning: if you select YES, this will clear the
memory and restart the system
4. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Related Items:
408
408i
iDCS100
IMPORTANT
None
All MMCs
MMC 812 (Page 1 of 1)
SELECT COUNTRY
iDCS500
OS500
DISPLAY
SELECT COUNTRY
U.K.
SELECT COUNTRY
DENMARK
DEFAULTING SYSTM
ARE YOU SURE?YES
MMC PROGRAMS
FEBRUARY 2004