Samsung DCS Programming Manual page 177

Combined systems
Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG
COMBINED SYSTEMS PROGRAMMING MANUAL
MMC: 426
FOR:
DCS
CII
Purpose: Allows loss levels (dB) to be adjusted on a per-trunk basis. Two adjustments
are available: "TX" is the transmit level adjustment of the trunk to the station; "RX" is the
receive level adjustment of the station to the trunk.
ACTION
1.
Open programming and select 426
Display shows
2.
Dial trunk number ( e.g., 704)
OR
Press VOLUME keys to select trunk and press
RIGHT soft key
OR
Select all trunks
3.
Press VOLUME keys to select trunk RX gain
and press RIGHT soft key
4.
Press VOLUME keys to select trunk TX gain
and press RIGHT soft key
5.
Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Related Items:
816
408
408i
(see section 1.5.2)
RX=+0.0, TX=+0.0 dB for all trunks
None
MMC 426 (Page 1 of 1)
TRUNK GAIN CONTROL
iDCS100
iDCS500
DISPLAY
[701] TRUNK GAIN
RX : +0.0 TX : +0.0
[704] TRUNK GAIN
RX : +0.0 TX : +0.0
OR
[ALL] TRUNK GAIN
RX : +0.0 TX : +0.0
[704] TRUNK GAIN
RX : +1.0 TX : +0.0
[704] TRUNK GAIN
RX : +1.0 TX : +1.0
MMC PROGRAMS
FEBRUARY 2004
OS500