Samsung DCS Programming Manual page 332

Combined systems
Hide thumbs Also See for DCS:
Table of Contents

Advertisement

SAMSUNG
COMBINED SYSTEMS PROGRAMMING MANUAL
MMC: 803
FOR:
DCS
iDCS500
Purpose: Assigns tenant groups on a per-cabinet, slot and port basis. The simple rule is
Cabinet-Slot-Port=Tenant. The only information needed is the correct correlation of en-
tries.
ACTION
1. Open programming and select 803
Display shows
2. Enter cabinet (C) number (if no change, press
RIGHT soft key to move cursor)
3. Enter slot (S) number (if no change, press RIGHT
soft key to move cursor)
4. Enter port (P) number (if no change, press RIGHT
soft key to move cursor)
5. Enter tenant (T) number (if no change, press
RIGHT soft key to return to step 2)
6. Press Transfer/TRSF to store and exit
OR
Press SPEAKER to store and advance to next
MMC
Default Data:
Related Items:
ASSIGN TENANT GROUP
OS500
All assignments tenant 1
Tenant group
MMC 803 (Page 1 of 1)
MMC PROGRAMS
FEBRUARY 2004
DISPLAY
TENANT GROUP
C:1 S:1 P:01 T:1
OR
TENANT GROUP
C:1 S:1 –01 T:1
TENANT GROUP
C:1 S:1 P:01 T:1
TENANT GROUP
C:1 S:1 P:01 T:1
TENANT GROUP
C:1 S:1 P:01 T:1
TENANT GROUP
C:1 S:1 P:01 T:1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents