Remote Aupc; Remote Aupc Configuration; Remote Aupc Monitor - Comtech EF Data SDM-300A Installation And Operation Manual

Hide thumbs Also See for SDM-300A:
Table of Contents

Advertisement

SDM-300A Satellite Modem
3.3.12

Remote AUPC

To view or change the Remote AUPC functions, enter the Remote AUPC menu from the
Function Select menu on the front panel. After entering the Remote AUPC menu, press
[←] or [→] to select the Configuration or Monitor menu. Enter the selected menu by
pressing [ENTER]. Press [←] or [→] to view the selected configuration parameters.
Note: This is only available with the ASYNC/AUPC overhead option.
3.3.12.1

Remote AUPC Configuration

Refer to Figure 3-15.
AUPC ENABLE
B-BAND LOOP BACK
TX 2047 PATTERN
3.3.12.2

Remote AUPC Monitor

Refer to Figure 3-16.
2047 ERRORS
Rev. 4
Programs the AUPC feature on or off.
Upon entry, the status of the remote AUPC is displayed. Press [↑] or [↓] to
make the selection. Press [ENTER] to execute the change.
Note: This program is for control or last known status.
Programs the remote baseband loopback on or off.
Upon entry, the status of the remote baseband loopback is displayed. Press
[↑] or [↓] to make the selection. Press [ENTER] to execute the change.
Note: This program is for control or last known status.
Programs the remote TX 2047 pattern on or off.
Upon entry, the status of the remote TX 2047 is displayed. Press [↑] or [↓]
to make the selection. Press [ENTER] to execute the change.
Note: This program is for control or last known status.
Receive 2047 BER. This is a monitor point that displays the current RX
2047 BER. If no data is available, "No Data" is displayed.