Specifications
C.8.1

Asynchronous Baud Rates

The operator can select the following baud rates for both the TX and RX asynchronous
overhead.
C.8.2

Asynchronous Overhead Data Format

The operator can select the following data formats for both the transmit and receive
asynchronous overhead.
C.8.3

Local Automatic Uplink Power Control (AUPC)

Note: AUPC functions are only available with ASYNC overhead.
The operator can select local AUPC to be Enabled or Disabled.
C.8.4

AUPC Power Levels

The operator can select from -5 to -30 dBm (+5 to -20 dBm for high power option) in
0.5 dBm steps, for the Nominal, Minimum, and Maximum TX power levels.
C.8.5

AUPC Target Noise Level

The operator can select the E
C.8.6

AUPC Tracking Rate

The operator can select the maximum tracking rate from 0.5 to 6.0 dBm/minute in
0.5 dBm/minute steps.
C–46
110
150
300
600
1200
Word Length
Stop Bits
5, 6, 7, or 8 bits
1 or 2 bits
/N
target setpoint from 3.2 to 16.0 dB in 0.1 dBm steps.
b
0
2400
4800
9600
19200
38400
Parity
Odd, Even, or None