Bulk Consol.
Status
(continued)
Parameter
Number
107
108
109
(Note 3)
110
(Note 4)
111
112
113
114
115
116
117
118
(Note 7)
119
(Note (8)
120
(Note 7)
121
(Note 7)
122
B–44
Parameter Name
(Command Reference)
RTS TX-IF Control Mode
(ref. 'RTSM_' command).
CTS Delay Time
(ref. 'CTSD_' command).
Carrier Only Mode
(ref. 'COM_' command).
IDR TX ESC Type
(ref. 'TET_' command).
IDR RX ESC Type
(ref. 'RET_' command).
TX Reed-Solomon Interleave Value
(ref. 'TRSI_' command).
RX Reed-Solomon Interleave
Value
(ref. 'RRSI_' command).
reserved null field.
reserved null field.
reserved null field.
TX 8PSK 2/3 IESS-310 Operation
(ref. 'T310_' command).
RX 8PSK 2/3 IESS-310 Operation
(ref. 'R310_' command).
Flex Mux Channel #1 Enable
(ref. "TCEN_1" command).
TX Flex Mux Channel #1 Data Rate
(ref. "TCDR_1" command).
TX Flex Mux Channel #2 Enable
(ref. "TCEN_2" command).
TX Flex Mux Channel #3 Enable
(ref. "TCEN_3" command).
Description
p107 = n, where 'n' is '0' (off) or '1' (on).
p108 = nn, CTS delay time in seconds.
p109 = n, where 'n' is '0' (OFF),'1' (CENTER-CW), '2'
(DUAL-CW), '3' (OFFSET-CW).
p110 = n, where 'n' is '0' (AUDIO), '1' (DATA).
p111 = n, where 'n' is '0' (AUDIO), '1' (DATA).
p112 = nn, Interleave value.
p113 = nn, Interleave value.
p117 = n, where 'n' is '0' (off) or '1' (on).
p118 = n, where 'n' is '0' (off) or '1' (on).
p119 = n, where 'n' is '0' (Disabled), '1' (D&I), or '2' (for
T1/E1) operation.
p120 = nnnn.n, where 'nnnn.n' is the data rate in Kbps.
p121 = n, where 'n' is '0' (Disabled), '1' (Enabled).
p122 = n, where 'n' is '0' (Disabled), '1' (Sync RS422), '2'
(Async RS422), '3' (Sync RS232), '4' (Async RS232), or '5'
(AUPC operation).