3.3.4

Configuration Local AUPC

Refer to Figure 3-7.
AUPC ENABLE
NOMINAL POWER
MINIMUM POWER
MAXIMUM POWER
TARGET NOISE
TRACKING RATE
LOCAL CL ACTION
REMOTE CL ACTION
Rev. 4
Programs the AUPC on or off.
Upon entry, the status is displayed. Press [↑] or [↓] to make the selection.
Press [ENTER] to execute the change.
Programs the nominal power value of the AUPC. The nominal power
value can range from -5 to -30 dBm, in 0.5 dBm steps.
Upon entry, the current nominal power value is displayed. Press [↑] or [↓]
to increment or decrement the digit at the flashing cursor. Press [ENTER]
to execute the change.
Programs the minimum power level of the AUPC. The minimum power
level can range from -5 to -30 dBm, in 0.5 dBm steps.
Upon entry, the current minimum power level is displayed. Press [↑] or [↓]
to increment or decrement the digit at the flashing cursor. Press [ENTER]
to execute the change.
Programs the maximum power level of the AUPC. The maximum power
level can range from -5 to -30 dBm, in 0.5 dBm steps.
Upon entry, the current maximum power level is displayed. Press [↑] or
[↓] to increment or decrement the digit at the flashing cursor. Press
[ENTER] to execute the change.
Programs the E
/N
target set point. The E
b
0
3.2 to 16.0 dB, in 0.1 dB steps.
Upon entry, the current E
/N
b
0
to increment or decrement the digit at the flashing cursor. Press [ENTER]
to execute the change.
Programs the maximum tracking rate of the AUPC.
Maximum tracking rate can range from 0.5 to 6.0 dBm/minute, in
0.5 dBm/minute steps.
Upon entry, the current maximum tracking rate is displayed. Press [↑] or
[↓] to increment or decrement the digit at the flashing cursor. Press
[ENTER] to execute the change.
Programs the local carrier loss for HOLD, NOMINAL, or MAXIMUM.
Upon entry, the status of the local carrier loss is displayed. Press [↑] or [↓]
to make the selection. Press [ENTER] to execute the change.
Programs the remote carrier loss for HOLD, NOMINAL, or MAXIMUM.
Upon entry, the status of the remote carrier loss is displayed. Press [↑] or
[↓] to make the selection. Press [ENTER] to execute the change.
/N
target set point ranges from
b
0
target set point is displayed. Press [↑] or [↓]
Operation