Comtech EF Data SDM-300A Installation And Operation Manual page 282

Hide thumbs Also See for SDM-300A:
Table of Contents

Advertisement

SDM-300A Satellite Modem
Sweep
Command:
Center
Response:
Frequency
Status:
Response:
Sweep
Command:
Width
Response:
Range
Status:
Response:
Sweep
Command:
Reacquisi-
Response:
tion
Status:
Response:
Bit Error
Command:
Rate
Response:
Threshold
Status:
Response:
Demodulato
Command:
r Type
Response:
Status:
Response:
Demodulato
Command:
r Decoder
Response:
Type
Status:
Response:
Demodulato
Command:
r Spectrum
Response:
Rotation
Status:
Response:
Reed-
Command:
Solomon
Response:
Decoder
Enable
Status:
Response:
Receive
Command:
BPSK Data
Response:
Ordering
Status:
Response:
RX Reed-
Command:
Solomon
Response:
Interleave
Value
Status:
Response:
RX 8PSK
Command:
2/3
Response:
IESS-310
Operation
Status:
Response:
Rev. 4
<add/SCF_snnnnn'cr'
>add/SCF_snnnnn'cr''lf']
<add/SCF_'cr'
>add/SCF_snnnnn'cr''lf']
<add/SWR_nnnnn'cr'
>add/SWR_nnnnn'cr''lf']
<add/SWR_'cr'
>add/SWR_nnnnn'cr''lf']
<add/SR_xxx'cr'
>add/SR_xxx'cr''lf']
<add/SR_'cr'
>add/SR_xxx'cr''lf']
<add/BERT_xxxx'cr'
>add/BERT_xxxx'cr''lf']
<add/BERT_'cr'
>add/BERT_xxxx'cr''lf']
<add/DT_xxxx'cr'
>add/DT_xxxx'cr''lf']
<add/DT_xxxx'cr'
>add/DT_xxxx'cr''lf']
<add/DDT_xxx'cr'
>add/DDT_xxx'cr''lf']
<add/DDT_xxx'cr'
>add/DDT_xxx'cr''lf']
<add/DSR_xxx'cr'
>add/DSR_xxx'cr''lf']
<add/DSR_'cr'
>add/DSR_xxx'cr''lf']
<add/RSDE_xxx'cr'
>add/RSDE_xxx'cr'lf']
<add/RSDE_'cr'
>add/RSDE_xxx'cr'lf']
<add/RDA_xxx'cr'
>add/RDA_xxx'cr''lf']
<add/RDA_xxx'cr'
>add/RDA_xxx'cr''lf']
<add/RRSI_xx'cr'
>add/RRSI_xx'cr''lf']
<add/RRSI_'cr'
>add/RRSI_xx'cr''lf']
<add/R310_xxx'cr'
>add/R310_xxx'cr''lf']
<add/R310_'cr'
>add/R310_xxx'cr''lf']
Where: snnnnn = -35000 to +35000, in 1 Hz steps.
Where: nnnnn = 0 to 70000, in 1 Hz steps.
Where: xxx = 0 to 999 (number of seconds).
Where: xxxx = NONE, or 1E-n, where n = 3, 4, 5, 6, 7, or 8
(exponent of threshold).
Where: xxxx = INTL (INTELSAT OPEN NETWORK), EFD
(EF DATA CLOSED NETWORK), CSC (COMSTREAM
CLOSED NETWORK), FDC (FAIRCHILD CLOSED
NETWORK).
Where: xxx = VIT (K-7 VITERBI ENCODER), SEQ
(SEQUENTIAL ENCODER).
Where: xxx = NRM (normal spectrum), INV (inverted
spectrum).
Where: xxx = ON, OFF, or CORR_OFF.
Where: xxx = NRM (STANDARD), INV (NON-
STANDARD).
Where: xx = 4, 8, or 16.
Where: xxx = ON or OFF.
Remote Control Operation
B–7

Advertisement

Table of Contents
loading

Table of Contents