Comtech EF Data SDM-300A Installation And Operation Manual page 327

Hide thumbs Also See for SDM-300A:
Table of Contents

Advertisement

Remote Control Operation
Built In Self
Command:
Test
Response:
Status:
Response:
State Of
Command:
Product
Response:
B–52
<add/BIST_xxxx'cr'
for (OFF or AUTO):
>add/BIST_xxxx'cr''lf']
for (RUN):
>add/BIST_xxxx'cr'
ST_xxx'cr''lf']
<add/BIST_xxxx'cr'
>add/BIST_xxxx'cr''lf']
<add/SOP_'cr'
>add/SOP_'cr'
add'cr'
abc'cr'
rrrrr bps'cr'
<var-string1>'cr'
<var-string2>'cr''lf']
Where: xxxx = OFF (self test disabled), RUN (run self test
now), AUTO (run self test on power up/software restart).
Self Test (OK/FLT)
Note: Allow 35 Seconds for response to RUN the Self Test.
Product Address
Data Format
Baud Rate
Comm Type
Where: abc = Explained below.
a = Number of data bits (7).
b = Parity type (O, E, N).
c = Number of stop bits (2).
rrrrr = baud rate ("150", "300", "600", "1200", "2400",
"4800", "9600", "14.4K", "19.2K").
<var-string1> = Variable length strings explaining
communication hardware type "RS-485, 2 wire", "RS-485,
4 wire", "RS-232".
<var_string2> = Variable length strings explaining the
intention of the product. "Under normal system operation",
"REFLASH of BULK firmware required", "REFLASH of
M&C firmware required".
SDM-300A Satellite Modem