Auxiliary 1 Connector And Pinouts (J9); Table 2-9. Aux 1 Connector And Pinouts (J9) - Comtech EF Data SDM-300A Installation And Operation Manual

Hide thumbs Also See for SDM-300A:
Table of Contents

Advertisement

Installation
2.3.4

Auxiliary 1 Connector and Pinouts (J9)

The auxiliary 1 (AUX 1) connector provides:
The faults are open collector levels that indicate a modulator or demodulator failure. A
logic "1" indicates the faulted condition.
AGC_OUT is a programmable voltage, 0 to 10V, for a receive signal level between -25 and
-60 dBm.
AUX 1 connection is a 9-pin female D connector (J9) located on the rear panel of the
modem. Screw locks are provided for mechanical security on the mating connector. Refer
to Table 2-9 for pinout information.
2–18
MOD and DEMOD (TTL) faults
Satellite clock
Satellite I&Q
Automatic Gain Control (AGC) output voltage

Table 2-9. AUX 1 Connector and Pinouts (J9)

Pin #
Signal Function
1
Satellite Clock -
2
No Connection
3
Satellite Clock +
4
MODULATOR TTL Fault
5
Ground
6
RX_Q
7
DEMODULATOR TTL Fault
8
RX 1 Channel Eye
9
Agc Output
SDM-300A Satellite Modem
Name
SAT_CLK-
NC
SAT_CLK+
MDFLTTTL
GRN
RX Q Channel Eye
RX_1
AGC
Rev. 4